DTC5150BX
DATA TECHNOLOGY CORPORATION
DTC5150BX
Data bus: 8-bit, ISA
Size: Full-length, full-height card
Hard drives supported: Two MFM ST506/412
Floppy drives supported: None
|
CONNECTIONS
|
|
Function
|
Location
|
|
34-pin control cable connector-hard drive
|
J1
|
|
20-pin data cable connector-drive 0
|
J2
|
|
20-pin data cable connector-drive 1
|
J3
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Location
|
Setting
|
| »
|
Sector size is set to 512 (Jumpers are hard wired)
|
W1
W2
|
closed
open
|
| »
|
BIOS address is C800 (This jumper is hard wired)
|
W5
|
closed
|
| »
|
BIOS enabled
|
W6
|
closed
|
|
|
BIOS disabled
|
W6
|
open
|
|
I/O PORT ADDRESS
|
|
Address
|
W3
|
W4
|
| »
|
320h
|
closed
|
closed
|
|
|
324h
|
open
|
closed
|
|
|
328h
|
closed
|
open
|
|
|
32Ch
|
open
|
open
|
|
BIOS DRIVE TYPE TABLE FOR THE BXD05 BIOS
|
|
Cap./Hds./ Cyls./WPC
|
SW1/3
|
SW1/4
|
SW1/7
|
SW1/8
|
|
5MB / 2 / 306 / 0
|
on
|
on
|
on
|
on
|
|
26MB / 8 / 375 / 0
|
off
|
on
|
on
|
on
|
|
15MB / 6 / 306 / 256
|
on
|
off
|
on
|
on
|
|
10MB / 4 / 306 / 0
|
off
|
off
|
on
|
on
|
|
5MB / 2 / 306 / 306
|
on
|
on
|
off
|
on
|
|
28MB / 5 / 640 / 640
|
off
|
on
|
off
|
on
|
|
20MB / 8 / 306 / 0
|
on
|
off
|
off
|
on
|
|
Reserved for Non-standard
|
off
|
off
|
off
|
on
|
|
18MB / 4 / 512 / 256
|
on
|
on
|
on
|
off
|
|
27MB / 6 / 512 / 256
|
off
|
on
|
on
|
off
|
|
10MB / 2 / 612 / 128
|
on
|
off
|
on
|
off
|
|
22MB / 4 / 640 / 256
|
off
|
off
|
on
|
off
|
|
18MB / 3 / 697 / 697
|
on
|
on
|
off
|
off
|
|
30MB / 5 / 697 / 697
|
off
|
on
|
off
|
off
|
|
33MB / 6 / 640 / 256
|
on
|
off
|
off
|
off
|
|
Split Drive Mode Setting
|
off
|
off
|
off
|
off
|
|
Note:SW1/3, SW1/4, SW1/7, and SW1/8 set the type for Drive 1, and SW1/1, SW1/2, SW1/5, and SW1/6 set the type for Drive 2
|
|