PM2021A/90, PM2021A/95
DISTRIBUTED PROCESSING TECHNOLOGY
PM2021A/90, PM2021A/95
|
Data bus:
|
16-bit, ISA (PM2021A/9x)
|
|
Size:
|
Half-length, full-height card
|
|
Hard drive supported:
|
Up to seven SCSI drives
|
|
Floppy drives supported:
|
Two 360KB, 720KB, 1.2MB, or 1.44MB drives (PM2x2x/95 only)
|
|
CONNECTIONS
|
|
Function
|
Location
|
|
CM4000 Cache Module Connector
|
P1
|
|
CM4000 Cache Module Connector
|
P2
|
|
DM4000 Disk Array Module Connector
|
P5
|
|
4-pin connector-Drive active LED
|
P6
|
|
DM400 Disk Array Module Connector
|
P7
|
|
34-pin control cable connector-floppy drive
|
P8
|
|
50-pin SCSI connector - internal
|
P10
|
|
50-pin SCSI connector - external
|
J11
|
|
DMA TRANSFER RATE
|
|
Speed
|
Jumper Y12
|
Jumper Y13
|
Jumper Y14
|
|
|
10MB/sec
|
open
|
open
|
open
|
|
|
8MB/sec
|
closed
|
open
|
open
|
|
|
6.667MB/sec
|
open
|
closed
|
open
|
|
|
5.7MB/sec
|
closed
|
closed
|
open
|
| »
|
5.0MB/sec
|
open
|
open
|
closed
|
|
|
4.4MB/sec
|
closed
|
open
|
closed
|
|
|
4.0MB/sec
|
open
|
closed
|
closed
|
|
|
3.0MB/sec
|
closed
|
closed
|
closed
|
|
SCSI ADDRESS
|
|
SCSI I.D.
|
Jumper Y18
|
Jumper Y25
|
Jumper Y26
|
|
|
0
|
open
|
open
|
open
|
|
|
1
|
open
|
closed
|
open
|
|
|
2
|
closed
|
open
|
open
|
|
|
3
|
closed
|
closed
|
open
|
|
|
4
|
open
|
open
|
closed
|
|
|
5
|
open
|
closed
|
closed
|
|
|
6
|
closed
|
open
|
closed
|
| »
|
7
|
closed
|
closed
|
closed
|
|
INTERRUPT REQUEST
|
|
IRQ
|
Y29
|
Y30
|
|
|
Disabled
|
open
|
open
|
|
|
IRQ12
|
open
|
closed
|
| »
|
IRQ15
|
closed
|
open
|
|
|
IRQ14
|
closed
|
closed
|
|
DMA CHANNEL
|
|
DRQ
|
Y31
|
Y32
|
|
|
DRQ0
|
open
|
open
|
|
|
DRQ7
|
open
|
closed
|
|
|
DRQ6
|
closed
|
open
|
| »
|
DRQ5
|
closed
|
closed
|
|
I/O PORT ADDRESS
|
|
Address
|
Y33
|
Y35
|
|
|
230h
|
open
|
open
|
| »
|
170h
|
open
|
closed
|
|
|
330h
|
closed
|
open
|
|
|
1F0h
|
closed
|
closed
|
|
BIOS ADDRESS
|
|
Address
|
Y36
|
Y37
|
|
|
Disabled
|
open
|
open
|
|
|
DC00h
|
open
|
closed
|
|
|
D800h
|
closed
|
open
|
| »
|
C800h
|
closed
|
closed
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Location
|
Setting
|
| »
|
DMA duty cycle is fast
|
Y15
|
open
|
|
|
DMA duty cycle is slow
|
Y15
|
closed
|
| »
|
SCSI termination enabled
|
Y16
|
closed
|
|
|
SCSI termination disabled
|
Y16
|
open
|
| »
|
Address LInes SA17-19 and LA17-19 driven
|
Y19
|
closed
|
|
|
Only Address LInes LA17-19 driven
|
Y19
|
open
|
| »
|
Floppy drive enabled
|
Y20
|
closed
|
|
|
Floppy drive disabled
|
Y20
|
open
|
| »
|
Bus Mastering enabled
|
Y24
|
closed
|
|
|
Bus Mastering disabled
|
Y24
|
open
|
| »
|
BIOS ROM size is 8K
|
Y38
|
open
|
|
|
BIOS ROM size is 16K
|
Y38
|
closed
|
| »
|
External SCSI cable detection disabled
|
Y39
|
open
|
|
|
External SCSI cable detection enabled*
|
Y39
|
closed
|
| »
|
Controller supplies TERMPWR to SCSI interface 26
|
Y50
|
closed
|
|
|
TERMPWR not supplied to SCSI Interface 26
|
Y50
|
open
|
|
STATUS LED'S
|
|
LED
|
Definition
|
|
LED 1
|
Busy
|
|
LED 2
|
Computer Bus Transfer to Adapter
|
|
LED 3
|
Computer Bus Transfer from Adapter
|
|
LED 4
|
Cache Hit
|
|
LED 5
|
Disk Read-Ahead Active
|
|
LED 6
|
Disk Read
|
|
LED 7
|
Disk Write
|
|
LED 8
|
Adapter Reset
|
|
LED 9
|
Interrupt Pending to Computer
|
|
LED 10
|
DRQ Asserted to Computer
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|
Detection of an external SCSI cable limits the maximum SCSI bus transfer rate to 5MB/sec.
The function of Jumper Y34 is unknown.
|
|