DAC960SX (DBX960S-3-UDR)
MYLEX CORPORATION
DAC960SX (DBX960S-3-UDR)
DAC960SX (DBX960S-6-UDR)
DAC960SX (DBX960S-6-FWR)
|
Card Type
|
Hard drive controller card
|
|
Processor
|
RISC
|
|
Maximum Onboard Memory
|
128MB DRAM (EDO supported)
|
|
Hard Drives supported
|
Up to 30 Ultra SCSI devices
|
|
Floppy drives supported
|
None
|
|
Data Bus
|
Up to two host Single-ended/Differential Wide Ultra-SCSI channels
|
|
Form Factor Size
|
5.25 inch
|
|
RAID levels supported
|
0, 1, 0+1, 3, 5, JBOD
|
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
LCD panel interface
|
J1
|
Diagnostic port
|
J6
|
|
Battery back-up
|
J2
|
Edge connector
|
J7
|
|
Daughterboard connector 1
|
J3
|
Edge connector
|
J8
|
|
Daughterboard connector 2
|
J4
|
|
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Channel 0 termination enabled
|
J5/pins 1 & 2
|
Closed
|
|
|
Channel 0 termination disabled
|
J5/pins 1 & 2
|
Open
|
| »
|
Channel 1 termination enabled
|
J5/pins 3 & 4
|
Closed
|
|
|
Channel 1 termination disabled
|
J5/pins 3 & 4
|
Open
|
| »
|
Host channel 0 termination enabled
|
J5/pins 5 & 6
|
Closed
|
|
|
Host channel 0 termination disabled
|
J5/pins 5 & 6
|
Open
|
| »
|
Factory configured - do not alter
|
J5/pins 7 & 8
|
Open
|
| »
|
Factory configured - do not alter
|
J5/pins 9 & 10
|
Open
|
|
DRAM CONFIGURATION
|
|
Size
|
Bank 0
|
|
8MB
|
(2) 1M x 36
|
|
16MB
|
(2) 2M x 36
|
|
32MB
|
(2) 4M x 36
|
|
64MB
|
(2) 8M x 36
|
|
128MB
|
(2) 16M x 36
|
|
TERMINATION CONFIGURATION
|
|
Notes: When using differential SCSI, external termination must be used and termination on the controller and daughterboard must be disabled. I.e., all termination jumpers (JP1/1-JP1/5) should be opened. (See User Configurable Settings.)
If Narrow SCSI (8-bit) is connected to any channel, the controller must be at one end of the bus with termination enabled (J5) on that channel.
If dual mode system, terminate SCSI bus externally.
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|
The DAC960SX controller (which can reside within a DAC9060SXI enclosure) interfaces between the host system and a disk array. The controller is installed with one of several distribution boards: DBX960X-3-UDR, DBX960S-6-FWR and DBX960S-6-UDR. A DBI960SX daughterboard can be installed with the latter two, providing a 3 channel upgrade. A battery backup unit can be installed with all.
|
DBX960SXI (ENCLOSURE)
DBX960SXI Front Panel
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
ESC key/return to previous screen
|
J1
|
Alarm key/reset audible alarm
|
ALARM
|
|
Keys defined by Instruction Line (last line of the LCD display menu
|
J2-J5
|
Unidentified
|
J7
|
|
Enter key/execute selected functions
|
J6
|
|
|
|
Card Type
|
Distribution board
|
|
Hard Drives supported
|
Up to 12 UltraSCSI Wide/Narrow devices
|
|
Floppy drives supported
|
None
|
|
Data Bus
|
One host Differential Wide Ultra-SCSI channel
|
Distribution Board DBX960S-3-UDR
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
10-pin serial port - internal
|
J1
|
50-pin SCSI channel 1 connector - internal
|
J8
|
|
68-pin SCSI connector -
host channel 0
|
J2
|
Power connector
|
J9
|
|
10-pin connector - dual controller communications port
|
J3
|
18-pin connector - channel 1 fault indicator
|
J10
|
|
68-pin SCSI channel 0 connector - internal
|
J4
|
18-pin connector - channel 0 fault indicator
|
J11
|
|
50-pin SCSI channel 0 connector -
internal
|
J5
|
20-pin connector - AEMI (Array Enclosure Management Interface)
|
J12
|
|
68-pin SCSI channel 1 connector -
internal
|
J7
|
Power connector
|
J13
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Factory configured - do not alter
|
J6/5
|
N/A
|
| »
|
Serial port protocol is SLP1
|
J6/6
|
Open
|
|
|
Serial port protocol is VT100
|
J6/6
|
Closed
|
| »
|
Factory configured - (serial port baud rate is 19.2)
|
J6/7
|
Closed
|
| »
|
Controller is only controller in system or
Controller is primary in two controller system
|
J6/8
|
Closed
|
|
|
Controller is secondary in two controller system
|
J6/8
|
Open
|
|
HOST CHANNEL SCSI ID SELECTION
|
|
SCSI ID
|
JP6/1
|
JP6/2
|
JP6/3
|
JP6/4
|
|
0
|
Open
|
Open
|
Open
|
Open
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Closed
|
Closed
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
5
|
Closed
|
Open
|
Closed
|
Open
|
|
6
|
Open
|
Closed
|
Closed
|
Open
|
|
7
|
Closed
|
Closed
|
Closed
|
Open
|
|
8
|
Open
|
Open
|
Open
|
Closed
|
|
9
|
Closed
|
Open
|
Open
|
Closed
|
|
10
|
Open
|
Closed
|
Open
|
Closed
|
|
11
|
Closed
|
Closed
|
Open
|
Closed
|
|
12
|
Open
|
Open
|
Closed
|
Closed
|
|
13
|
Closed
|
Open
|
Closed
|
Closed
|
|
14
|
Open
|
Closed
|
Closed
|
Closed
|
|
15
|
Closed
|
Closed
|
Closed
|
Closed
|
|
TERMINATION CONFIGURATION
|
|
Note: Differential resistor packs RP1, RP2 and RP3 must be installed to enable Host Channel 0 termination and removed to disable termination.
|
|
Card Type
|
Distribution board
|
|
Hard Drives supported
|
Up to 30 UltraSCSI Wide/Narrow devices
|
|
Floppy drives supported
|
None
|
|
Data Bus
|
Up to two host Ultra-SCSI Wide channels
|
Distribution Board DBX960S-6-FWR
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
68-pin SCSI drive channel 2 connector - internal
|
J1
|
20-pin connector - AEMI (Array Enclosure Management Interface)
|
J10
|
|
68-pin SCSI drive channel 0 connector - internal
|
J2
|
Power connector
|
J11
|
|
68-pin SCSI drive channel 3 connector - internal
|
J3
|
10-pin serial port connector
|
J12
|
|
68-pin SCSI drive channel 1 connector - internal
|
J4
|
18-pin connector - drive channel 1 fault indicator
|
J13
|
|
68-pin SCSI host channel 1/drive channel 4 - internal
|
J5
|
18-pin connector - drive channel 0 fault indicator
|
J14
|
|
68-pin SCSI host channel 0 connector - internal
|
J7
|
18-pin connector - drive channel 2 fault indicator
|
J15
|
|
Power connector
|
J8
|
18-pin connector - drive channel 3 fault indicator
|
J16
|
|
18-pin connector - drive channel 4 fault indicator
|
J9
|
10-pin connector - dual controller communications port
|
J17
|
|
Note: Host channel 1 and drive channels 2 and 3 are only available if daughterboard DBI960SX is installed.
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Factory configured - do not alter
|
J6/5
|
N/A
|
| »
|
Serial port protocol is SLP1
|
J6/6
|
Open
|
|
|
Serial port protocol is VT100
|
J6/6
|
Closed
|
| »
|
Factory configured - (serial port baud rate is 19.2)
|
J6/7
|
Closed
|
| »
|
Controller is only controller in system or
Controller is primary in two controller system
|
J6/8
|
Closed
|
|
|
Controller is secondary in two controller system
|
J6/8
|
Open
|
|
HOST CHANNEL 0 SCSI ID SELECTION
|
|
SCSI ID
|
JP6/1
|
JP6/2
|
JP6/3
|
JP6/4
|
|
0
|
Open
|
Open
|
Open
|
Open
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Closed
|
Closed
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
5
|
Closed
|
Open
|
Closed
|
Open
|
|
6
|
Open
|
Closed
|
Closed
|
Open
|
|
7
|
Closed
|
Closed
|
Closed
|
Open
|
|
8
|
Open
|
Open
|
Open
|
Closed
|
|
9
|
Closed
|
Open
|
Open
|
Closed
|
|
10
|
Open
|
Closed
|
Open
|
Closed
|
|
11
|
Closed
|
Closed
|
Open
|
Closed
|
|
12
|
Open
|
Open
|
Closed
|
Closed
|
|
13
|
Closed
|
Open
|
Closed
|
Closed
|
|
14
|
Open
|
Closed
|
Closed
|
Closed
|
|
15
|
Closed
|
Closed
|
Closed
|
Closed
|
|
HOST CHANNEL 1 SCSI ID SELECTION
|
|
SCSI ID
|
J6/9
|
J6/10
|
J6/11
|
J6/12
|
|
0
|
Open
|
Open
|
Open
|
Open
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Closed
|
Closed
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
5
|
Closed
|
Open
|
Closed
|
Open
|
|
6
|
Open
|
Closed
|
Closed
|
Open
|
|
7
|
Closed
|
Closed
|
Closed
|
Open
|
|
8
|
Open
|
Open
|
Open
|
Closed
|
|
9
|
Closed
|
Open
|
Open
|
Closed
|
|
10
|
Open
|
Closed
|
Open
|
Closed
|
|
11
|
Closed
|
Closed
|
Open
|
Closed
|
|
12
|
Open
|
Open
|
Closed
|
Closed
|
|
13
|
Closed
|
Open
|
Closed
|
Closed
|
|
14
|
Open
|
Closed
|
Closed
|
Closed
|
|
15
|
Closed
|
Closed
|
Closed
|
Closed
|
|
Card Type
|
Distribution board
|
|
Hard Drives supported
|
Up to 24 UltraSCSI Wide/Narrow devices
|
|
Floppy drives supported
|
None
|
|
Data Bus
|
Up to two Differential Wide Ultra-SCSI channels
|
Distribution Board DBX960S-6-UDR
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
68-pin SCSI drive channel 2 connector - internal
|
J1
|
68-pin SCSI host channel 0 connector - internal
|
J7
|
|
68-pin SCSI drive channel 3 connector - internal
|
J2
|
Power connector
|
J8
|
|
68-pin SCSI drive channel 0 connector - internal
|
J3
|
10-pin serial port connector
|
J9
|
|
68-pin SCSI drive channel 1 connector - internal
|
J4
|
80-pin connector - fault and status port
|
J10
|
|
68-pin SCSI host channel 1 connector - internal
|
J5
|
10-pin connector - reserved for testing
|
J11
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Factory configured - do not alter
|
J6/5
|
N/A
|
| »
|
Serial port protocol is SLP1
|
J6/6
|
Open
|
|
|
Serial port protocol is VT100
|
J6/6
|
Closed
|
| »
|
Factory configured - (serial port baud rate is 19.2)
|
J6/7
|
Closed
|
| »
|
Controller is only controller in system or
Controller is primary in two controller system
|
J6/8
|
Closed
|
|
|
Controller is secondary in two controller system
|
J6/8
|
Open
|
|
HOST CHANNEL 0 SCSI ID SELECTION
|
|
SCSI ID
|
JP6/1
|
JP6/2
|
JP6/3
|
JP6/4
|
|
0
|
Open
|
Open
|
Open
|
Open
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Closed
|
Closed
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
5
|
Closed
|
Open
|
Closed
|
Open
|
|
6
|
Open
|
Closed
|
Closed
|
Open
|
|
7
|
Closed
|
Closed
|
Closed
|
Open
|
|
8
|
Open
|
Open
|
Open
|
Closed
|
|
9
|
Closed
|
Open
|
Open
|
Closed
|
|
10
|
Open
|
Closed
|
Open
|
Closed
|
|
11
|
Closed
|
Closed
|
Open
|
Closed
|
|
12
|
Open
|
Open
|
Closed
|
Closed
|
|
13
|
Closed
|
Open
|
Closed
|
Closed
|
|
14
|
Open
|
Closed
|
Closed
|
Closed
|
|
15
|
Closed
|
Closed
|
Closed
|
Closed
|
|
HOST CHANNEL 1 SCSI ID SELECTION
|
|
SCSI ID
|
J6/9
|
J6/10
|
J6/11
|
J6/12
|
|
0
|
Open
|
Open
|
Open
|
Open
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Closed
|
Closed
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
5
|
Closed
|
Open
|
Closed
|
Open
|
|
6
|
Open
|
Closed
|
Closed
|
Open
|
|
7
|
Closed
|
Closed
|
Closed
|
Open
|
|
8
|
Open
|
Open
|
Open
|
Closed
|
|
9
|
Closed
|
Open
|
Open
|
Closed
|
|
10
|
Open
|
Closed
|
Open
|
Closed
|
|
11
|
Closed
|
Closed
|
Open
|
Closed
|
|
12
|
Open
|
Open
|
Closed
|
Closed
|
|
13
|
Closed
|
Open
|
Closed
|
Closed
|
|
14
|
Open
|
Closed
|
Closed
|
Closed
|
|
15
|
Closed
|
Closed
|
Closed
|
Closed
|
|
Card Type
|
Daughterboard
|
|
Hard Drives supported
|
Up to 18 UltraSCSI Wide/Narrow devices
|
|
Floppy drives supported
|
None
|
|
Data Bus
|
One Single-ended/Differential Wide Ultra-SCSI channel
|
DBI960SX Daughterboard
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
Edge connector (drive)
|
CN1
|
DAC960SX controller connector
|
J2
|
|
Edge connector (drive)
|
CN2
|
DAC960SX controller connector
|
J3
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Channel 2 termination enabled
|
JP1/1
|
Closed
|
|
|
Channel 2 termination disabled
|
JP1/1
|
Open
|
| »
|
Channel 3 termination enabled
|
JP1/2
|
Closed
|
|
|
Channel 3 termination disabled
|
JP1/2
|
Open
|
| »
|
Channel 4 termination enabled
|
JP1/3
|
Closed
|
|
|
Channel 4 termination disabled
|
JP1/3
|
Open
|
| »
|
Factory configured - do not alter
|
JP1/4
|
Open
|
| »
|
Factory configured - do not alter
|
JP1/5
|
Open
|
|
TERMINATION CONFIGURATION
|
|
Notes: All termination jumpers (JP1/1-JP1/5) should remain closed on the daughterboard unless operating in dual host mode or using a differential SCSI distribution board.
When using differential SCSI, external termination must be used and termination on the controller and daughterboard must be disabled. All termination jumpers (JP1/1-JP1/5 should be opened.)
If dual host mode is not used, all JP1 termination jumpers should be closed.
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|
The DBI960SX supports three SCSI channels. Two are drive channels and the third can be configured as either a second host channel or a third drive channel.
|
Battery Backup Unit
|
CONNECTIONS
|
|
Function
|
Location
|
Function
|
Location
|
|
3-pin connector - external battery source
|
J1
|
2-pin connector - VCC source for external LED
|
J4
|
|
12-pin connector to controller board
|
J3
|
|
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Backup power source is internal (on-board batteries)
|
J2
|
INT
|
|
|
Backup power source is external (off-board batteries)
|
J2
|
EXT
|
|
Note: J2 is located on the reverse side of the Battery Backup card.
|
|
REFRESH TIMING SELECTION
|
|
Timing
|
J5
|
J6
|
|
Self-refresh
|
N/A
|
SELF
|
|
Normal refresh
|
NORM
|
C/R
|
|
Extended refresh
(for low power memory
|
LPWR
|
C/R
|
|