S-DCB
PROCOMP USA, INC.
S-DCB
|
Data bus:
|
16-bit, ISA
|
|
Size:
|
Full-length, full-height card
|
|
Hard drive supported:
|
Up to seven SCSI drives
|
|
Floppy drives supported:
|
360KB, 720KB, 1.2MB, or 1.44MB (2)
|
|
CONNECTIONS
|
|
Purpose
|
Location
|
|
SCSI drive interface (50 pin) internal
|
CN1
|
|
SCSI drive interface (25 pin) external
|
CN2
|
|
Floppy drive interface
|
CN3
|
|
UPS/status output cable
|
CN4
|
|
Hard Drive activity LED
|
CN6
|
|
CHANNEL SELECT CONFIGURATION
|
|
Channel
|
I/O Address
|
IRQ
|
SW1/switch 1
|
SW1/switch 2
|
SW1/switch 3
|
|
1
|
340h
|
IRQ11
|
off
|
off
|
on
|
|
2
|
348h
|
IRQ12
|
on
|
on
|
on
|
|
3
|
320h
|
IRQ10
|
off
|
on
|
on
|
|
4
|
328h
|
IRQ15
|
on
|
off
|
on
|
|
5
|
380h
|
IRQ10
|
off
|
on
|
off
|
|
6
|
388h
|
IRQ15
|
on
|
off
|
off
|
|
Disabled
|
N/A
|
N/A
|
on
|
on
|
off
|
|
Disabled
|
N/A
|
N/A
|
off
|
off
|
off
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Location
|
Setting
|
| »
|
Controller supplies TERMPWR to SCSI interface 26
|
JP1
|
pins 2 & 3 closed
|
|
|
TERMPWR not supplied to SCSI Interface 26
|
JP1
|
pins 1 & 2 closed
|
| »
|
UPS uses open contact to indicate"Battery Low"
|
JP4
|
open
|
|
|
UPS uses closed contact to indicate"Battery Low"
|
JP4
|
closed
|
| »
|
UPS uses open contact to indicate"On-Line"
|
JP5
|
open
|
|
|
UPS uses closed contact to indicate"On-Line"
|
JP5
|
closed
|
| »
|
Floppy drive enabled
|
SW1/switch 7
|
on
|
|
|
Floopy drive disabled
|
SW1/switch 7
|
off
|
| »
|
SCSI parity check enabled
|
SW1/switch 8
|
on
|
|
|
SCSI parity check disabled
|
SW1/switch 8
|
off
|
|
BIOS ADDRESS CONFIGURATION
|
|
Address
|
SW1/switch 5
|
SW1/switch 6
|
SW1/switch 7
|
|
Disabled
|
off
|
off
|
off
|
|
DC00h
|
off
|
off
|
on
|
|
DA00h
|
off
|
on
|
off
|
|
D800h
|
off
|
on
|
on
|
|
CE00h
|
on
|
off
|
off
|
|
CCOOh
|
on
|
off
|
on
|
|
CA00h
|
on
|
on
|
off
|
|
C800h
|
on
|
on
|
on
|
|