HIGH SPEED SSA DATA PUMP
PATHLIGHT TECHNOLOGY
HIGH SPEED SSA DATA PUMP
|
Card Type
|
Data Pump
|
|
Chip Set
|
Intel
|
|
Maximum Onboard Memory
|
512KB EPROM, 256KB SRAM
|
|
I/O Options
|
SSA interface via 9 pin serial ports (2 RS-232), Host-Side PCI bus, Top edge test card connector
|
|
Data Bus
|
32-bit PCI
|
|
Card Size
|
Half-length
|
|
CONNECTIONS
|
|
Function
|
Label
|
Function
|
Label
|
|
Host-side PCI bus
|
CN3
|
9-pin serial port 1
|
J1
|
|
Top edge test card connector
|
CN4
|
9-pin serial port 2
|
J3
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
|
Port 1 external SSA connector enabled
|
J2
|
Pins 3 & 4, 5 & 6, 11 & 12, 13 & 14 closed
|
|
Port 1 external SSA connector disabled
|
J2
|
Open
|
|
Port 2 external SSA connector enabled
|
J3
|
Pins 3 & 4, 5 & 6, 11 & 12, 13 & 14 closed
|
|
Port 2 external SSA connector disabled
|
J3
|
Open
|
|
Note:
If an SSA application does not require the use of external serial ports, a custom cable may be used to connect the odd number pins of J2 and/or J4 to an internal device loop.
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED 1
|
Green
|
On
|
Firmware loaded and executed
|
|
LED 1
|
Green
|
Off
|
Firmware not loaded and executing or a serious error condition exists
|
|
LED 2
|
Red
|
On
|
One or more SSA ports are active
|
|
LED 2
|
Red
|
Off
|
No ports are active
|
|