EN-6360 (Version 1.1)
EDIMAX COMPUTER COMPANY
EN-6360 (Version 1.1)
|
NIC Type
|
Ethernet
|
|
Transfer Rate
|
10Mbps
|
|
Data Bus
|
16-bit ISA
|
|
Topology
|
Star
|
|
Wiring Type
|
Unshielded twisted pair
AUI transceiver via DB-15 port
|
|
Boot ROM
|
Available
|
|
COMPATIBILITY MODE
|
|
Setting
|
JP6
|
| »
|
DIsabled
|
Pins 1 & 2 closed
|
|
|
Enabled
|
Pins 2 & 3 closed
|
|
Note: On some systems the data bus timing is not truly IBM PC/AT compatible. If the card is not initializing, enabling the compatibility mode may allow the card to function properly
|
|
BOOT ROM ADDRESS
|
|
Address
|
JP7A
|
JP7B
|
JP7C
|
JP7D
|
|
|
C0000h
|
Closed
|
Closed
|
Closed
|
Closed
|
|
|
C4000h
|
Open
|
Closed
|
Closed
|
Closed
|
| »
|
C8000h
|
Closed
|
Open
|
Closed
|
Closed
|
|
|
CC000h
|
Open
|
Open
|
Closed
|
Closed
|
|
|
D0000h
|
Closed
|
Closed
|
Open
|
Closed
|
|
|
D4000h
|
Open
|
Closed
|
Open
|
Closed
|
|
|
D8000h
|
Closed
|
Open
|
Open
|
Closed
|
|
|
DC000h
|
Open
|
Open
|
Open
|
Closed
|
|
BOOT ROM
|
|
Setting
|
JP8
|
| »
|
Disabled
|
Open
|
|
|
Enabled
|
Closed
|
|
CABLE TYPE
|
|
Type
|
JP10A-JP10F
|
JP11
|
| »
|
Unshielded twisted pair
|
Pins 1 & 2 closed
|
Pins 2 & 3 closed
|
|
|
AUI transceiver via DB-15 port
|
Pins 2 & 3 closed
|
Pins 1 & 2 closed
|
|
I/O BASE ADDRESS
|
|
Address
|
JP12A
|
JP12B
|
| »
|
300h
|
Closed
|
Closed
|
|
|
320h
|
Open
|
Closed
|
|
|
340h
|
Closed
|
Open
|
|
|
360h
|
Open
|
Open
|
|
INTERRUPT SETTINGS
|
|
IRQ
|
JP12C
|
JP12D
|
JP12E
|
JP12F
|
|
|
2
|
Closed
|
Open
|
Open
|
Open
|
| »
|
3
|
Open
|
Closed
|
Open
|
Open
|
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
|
|
5
|
Open
|
Open
|
Open
|
Closed
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Green
|
On
|
Data is being transmitted
|
|
LED1
|
Green
|
Off
|
Data is not being transmitted
|
|
LED2
|
Green
|
On
|
Data is being received
|
|
LED2
|
Green
|
Off
|
Data is not being received
|
|
LED3
|
Red
|
On
|
Twisted pair connection is good
|
|
LED3
|
Red
|
Off
|
Twisted pair connection is broken
|
|