1000A V2.4
EDIMAX COMPUTER COMPANY
1000A V2.4
|
NIC Type
|
Ethernet
|
|
Transfer Rate
|
10Mbps
|
|
Data Bus
|
8-bit ISA
|
|
Topology
|
Star
Linear Bus
|
|
Wiring Type
|
RG-58A/U 50ohm coaxial
Unshielded twisted pair
AUI transceiver via DB-15 port
|
|
Boot ROM
|
Available
|
|
I/O BASE ADDRESS
|
|
Address
|
JP1A
|
JP1B
|
JP1C
|
| »
|
300h
|
Closed
|
Closed
|
Closed
|
|
|
320h
|
Closed
|
Closed
|
Open
|
|
|
340h
|
Closed
|
Open
|
Closed
|
|
|
360h
|
Closed
|
Open
|
Open
|
|
INTERRUPT SETTINGS
|
|
IRQ
|
JP1D
|
JP1E
|
JP1F
|
JP1G
|
JP1H
|
JP1I
|
|
2
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
3
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
|
5
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
|
6
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
|
7
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
|
DMA CHANNEL
|
|
Channel
|
JP1J
|
JP1K
|
JP1L
|
JP1M
|
| »
|
Disabled
|
Closed
|
Open
|
Closed
|
Open
|
|
|
DMA1
|
Closed
|
Open
|
Closed
|
Open
|
|
|
DMA3
|
Open
|
Closed
|
Open
|
Closed
|
|
CONNECTORS
|
|
Setting
|
Location
|
|
External power LED.
|
JP2
|
|
BOOT ROM ADDRESS
|
|
Address
|
JP3A
|
JP3B
|
JP3C
|
JP3D
|
|
|
C0000h
|
Closed
|
Closed
|
Closed
|
Closed
|
|
|
C4000h
|
Open
|
Closed
|
Closed
|
Closed
|
| »
|
C8000h
|
Closed
|
Open
|
Closed
|
Closed
|
|
|
CC000h
|
Open
|
Open
|
Closed
|
Closed
|
|
|
D0000h
|
Closed
|
Closed
|
Open
|
Closed
|
|
|
D4000h
|
Open
|
Closed
|
Open
|
Closed
|
|
|
D8000h
|
Closed
|
Open
|
Open
|
Closed
|
|
|
DC000h
|
Open
|
Open
|
Open
|
Closed
|
|
CABLE TYPE
|
|
Type
|
JP4
|
JP10A-JP10F
|
JP11
|
| »
|
RG-58A/U 50ohm coaxial
|
Pins 2 & 3 Closed
|
Open
|
Pins 2 & 3 Closed
|
|
|
AUI transceiver via DB-15 port
|
Pins 1 & 2 Closed
|
Open
|
Pins 1 & 2 Closed
|
|
|
Unshielded twisted pair
|
Pins 1 & 2 Closed
|
Closed
|
Pins 2 & 3 Closed
|
|
BOOT ROM
|
|
Setting
|
JP5
|
| »
|
Disabled
|
Open
|
|
|
Enabled
|
Closed
|
|
AUTOPOLARITY
|
|
Setting
|
JP6
|
| »
|
Enabled
|
Pins 1 & 2 Closed
|
|
|
Disabled
|
Pins 2 & 3 Closed
|
|
Note: If disabled, and the network wire polarities are reversed, the card will be damaged.
|
|
LINK INTEGRITY
|
|
Setting
|
JP7
|
| »
|
Enabled
|
Pins 2 & 3 Closed
|
|
|
Disabled
|
Pins 1 & 2 Closed
|
|
Note: If this option is disabled, SQE is also disabled and Cable Length is set to 185 meters
|
|
SIGNAL QUALITY ERROR (SQE) TEST
|
|
Setting
|
JP8
|
| »
|
Enabled
|
Pins 1 & 2 Closed
|
|
|
Disabled
|
Pins 2 & 3 Closed
|
|
Note:Signal Quality Error (SQE) is a test of the collision circuitry and path.
Link integrity must be enabled for SQE to be enabled.
|
|
CABLE LENGTH SELECT
|
|
Setting
|
JP13
|
| »
|
185 meters
|
Pins 1 & 2 Closed
|
|
|
305 meters
|
Pins 2 & 3 Closed
|
|
Note: All cards on the network segment must have this function set the same.
Link integrity must be enabled to select long cable length.
|
|
FACTORY CONFIGURED SETTINGS
|
|
Jumper
|
Setting
|
|
JP9
|
Unused
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Yellow
|
Off
|
Normal operation
|
|
LED1
|
Yellow
|
On
|
A reversed twisted pair is detected and corrected
|
|
LED2
|
Green
|
On
|
Twisted pair network connection is good
|
|
LED2
|
Green
|
Off
|
Twisted pair network connection is broken
|
|