201
EXOS
201
|
NIC Type
|
Ethernet
|
|
Transfer Rate
|
10Mbps
|
|
Data Bus
|
Multibus
|
|
Topology
|
Linear bus
|
|
Wiring Type
|
AUI transceiver via DB-15 on sub-connector
|
|
Boot ROM
|
Available (in firmware)
|
|
FACTORY CONFIGURED
|
|
Jumper
|
Setting
|
|
J2
|
Closed
|
|
J3
|
Open
|
|
J9
|
Open
|
|
J10
|
Closed
|
|
J12
|
Open
|
|
J61
|
Closed
|
|
ONBARD BUFFER RAM
|
|
Size
|
J4
|
J7
|
|
128KB
|
Open
|
Open
|
|
256KB
|
Open
|
Closed
|
|
512KB
|
Closed
|
Open
|
|
CARRIER SENSE CONFIGURATION
|
|
Setting
|
J5
|
| »
|
Carrier sense enabled
|
Open
|
|
|
Carrier sense disabled
|
Closed
|
|
Note:Carrier sense should be disabled when using a broad-band transceiver.
|
|
BOOT ROM
|
|
Setting
|
J6
|
|
Enabled
|
Closed
|
|
Disabled
|
Open
|
|
SIGNAL QUALITY CONFIGURATION
|
|
Setting
|
J11
|
| »
|
Signal quality check enabled
|
Closed
|
|
|
Signal quality check disabled
|
Open
|
|
Note:Signal quality checking should be disabled in any Ethernet version 1 installation.
|
|
MULTIBUS I/O (SLAVE) ACCESS CONFIGURATION
|
|
The EXOS 201 supports two simultaneous I/O ports, labeled port A and port B. In addition, the 201 supports either 8-bit or 16-bit memory addressing. When in 16-bit addressing mode, the port A address is selectable via jumper J52 & J53. Jumper J52A-G defines bits 1-7 of the memory address respectively, and J53A-H defines bits 8-15 respectively (when a jumper is closed, the bit that it corresponds to is set to 1; when open, the bit is set to 0.). For expample, if JP52A is closed, and JP52B-G & JP53A-H are open, the memory address selected is 0001h. When in 8-bit addressing mode, JP52A-G select bits 1-7 respectively, and JP53 is inactive. Regardless of the memory addressing mode, port B will always be located 1 byte above port A's address (e.g. Port A = 0001h, Port B = 0002h). Bit 0 is always set to 0 for port A, and 1 for port B. (Open=0, closed=1)
|
|
MULTIBUS MEMORY ADDRESSING METHOD
|
|
Memory Address
|
J50
|
J51
|
|
8-bit memory addressing
|
Open
|
Closed
|
|
16-bit memory addressing
|
Closed
|
Open
|
|
44-PIN ISBX CONNECTOR CONFIGURATION
|
|
The iSBX connector (IEEE P969 specification), is included for daughterboard options. There are two jumper-selectable interrupt lines (J13 and J14) which should be left open unless an optional daugherboard is installed. If a daughterboard is installed, one jumper or the other must be closed, but not both. JP13 closed selects IR0, JP14 selects IR1.
|
|
WATCHDOG TIMER CONFIGURATION
|
|
Setting
|
J15
|
|
Watchdog timer enabled
|
Open
|
|
Watchdog timer disabled
|
Closed
|
|
MULTIBUS INTERRUPT ACCESS
|
|
INT
|
J54A
|
J54B
|
J54C
|
J54D
|
J54E
|
J54F
|
J54G
|
J54H
|
|
0
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
|
1
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
|
2
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
|
5
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
6
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
7
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
USER PROGRAMMABLE EPROM TYPE
|
|
Type
|
J55
|
J56
|
|
27128
|
Closed
|
Open
|
|
27256
|
Open
|
Closed
|
|
None
|
Open
|
Open
|
|
MULTIBUS PRIORITY RESOLUTION METHOD
|
|
Resolution Scheme
|
J57
|
| »
|
Enabled
|
Closed
|
|
|
Disabled
|
Open
|
|
BUS ARBITRATION
|
|
Setting
|
J58
|
J59
|
| »
|
Disabled
|
Open
|
Closed
|
|
|
Enabled
|
Closed
|
Open
|
|
CLOCK CONFIGURATION
|
|
Setting
|
J60
|
|
/CCLK and /BCLK bus driven
|
Open
|
|
/CCLK and /BCLK card driven
|
Closed
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Status
|
Condition
|
|
1
|
On
|
Performing power on self tests
|
|
1
|
Flashing
|
Waiting for host or network initialization
|
|
1
|
Off
|
Card succesfully inserted into network
|
|
2
|
On
|
Data is being transmitted
|
|
2
|
Off
|
Data is not being transmitted
|
|
3
|
On
|
Attempted access to non-existant memory location on multibus
|
|
3
|
Pulsing
|
Multibus cycle in progress
|
|
3
|
Off
|
No multibus cycle in progress
|
|