MAGNUM CT1A
GARRETT COMMUNICATIONS
MAGNUM CT1A
|
Card Type
|
Ethernet Transceiver
|
|
NIC Type
|
Ethernet
|
|
Maximum Onboard Memory
|
Unidentified
|
|
Boot ROM
|
Not available
|
|
Network Transfer Rate
|
10Mbps
|
|
Topology
|
Linear Bus
|
|
Wiring Type
|
AUI transceiver via DB-15 port, RG-58A/U 50ohm coaxial
|
|
Data Bus
|
External
|
|
CONNECTIONS
|
|
Function
|
Label
|
Function
|
Label
|
|
AUI transceiver via DB-15
|
CN1
|
RG-58A/U 50ohm coaxial
|
CN2
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
SQE enabled
|
SW1
|
On
|
|
|
SQE disabled
|
SW1
|
Off
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Green
|
On
|
Power is on
|
|
LED1
|
Green
|
Off
|
Power is off
|
|
LED2
|
Yellow
|
On
|
SQE is enabled
|
|
LED2
|
Yellow
|
Off
|
SQE is disabled
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|
The AUI port should be directly connected to the workstation. If you cannot connect to the workstation directly, an AUI drop cable (which cannot exceed 3 feet in length) may be used.
|
|