MAGNUM TP1
GARRETT COMMUNICATIONS
MAGNUM TP1
|
Card Type
|
Ethernet Transceiver
|
|
NIC Type
|
Ethernet
|
|
Maximum Onboard Memory
|
Unidentified
|
|
Boot ROM
|
Not available
|
|
Network Transfer Rate
|
10Mbps
|
|
Topology
|
Linear Bus, Star
|
|
Wiring Type
|
Shielded twisted pair, Unshielded twisted pair
AUI transceiver via DB-15 port
|
|
Data Bus
|
External
|
|
CONNECTIONS
|
|
Function
|
Label
|
Function
|
Label
|
|
AUI transceiver via DB-15
|
CN1
|
UTP/STP connector (RJ-45)
|
CN2
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
| »
|
Automatic correction for reversed polarity enabled
|
SW1
|
On
|
|
|
Automatic correction for reversed polarity disabled
|
SW1
|
Off
|
| »
|
Unshielded twisted pair
|
SW2
|
Off
|
|
|
Shielded twisted pair
|
SW2
|
On
|
| »
|
10BASE-T enabled
|
SW3
|
On
|
|
|
Starlan 10 (ATT) polarity on the segment
|
SW3
|
Off
|
| »
|
SQE enabled
|
SW4
|
On
|
|
|
SQE disabled
|
SW4
|
Off
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Green
|
On
|
Network connection established
|
|
LED1
|
Green
|
Off
|
Network connection is not established
|
|
LED2
|
Yellow
|
On
|
Collision has occurred
|
|
LED2
|
Yellow
|
Off
|
Collision has not occurred
|
|
LED3
|
Green
|
Blinking
|
Data is being received
|
|
LED3
|
Green
|
Off
|
Data is not being received
|
|
LED4
|
Green
|
On
|
Data is being transmitted
|
|
LED4
|
Green
|
Off
|
Data is not being transmitted
|
|
LED5
|
Yellow
|
On
|
Polarity error
|
|
LED5
|
Yellow
|
Off
|
No polarity error
|
|
LED6
|
Yellow
|
On
|
SQE test feature enabled
|
|
LED6
|
Yellow
|
Off
|
SQE test feature disabled
|
|
LED7
|
Green
|
On
|
Power is on
|
|
LED7
|
Green
|
Off
|
Power is off
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|