PD1516PLUS
PURE DATA LTD.
PD1516PLUS
|
NIC Type
|
ARCnet
|
|
Transfer Rate
|
2.5Mbps
|
|
Data Bus
|
16-bit ISA
|
|
Topology
|
Linear Bus
|
|
Wiring Type
|
RG-62A/U 93ohm coaxial
|
|
Boot ROM
|
Available
|
|
CONFIGURATION MEMORY CLEAR
|
|
Clear
|
JP1
|
| »
|
Normal operation
|
Open
|
|
|
Clear all addresses and settings from memory
|
Closed
|
|
CARDS INSTALLED
|
|
Card number
|
JP2A
|
JP2B
|
JP2C
|
JP2D
|
|
1
|
Closed
|
Open
|
Open
|
Open
|
|
2
|
Open
|
Closed
|
Open
|
Open
|
|
3
|
Open
|
Open
|
Closed
|
Open
|
|
4
|
Open
|
Open
|
Open
|
Closed
|
|
Note:If there is only one NIC installed in a system, set this option to the "1" position. If this NIC is the second NIC to be installed in a system, set this option to the "2" position and so on.
|
|
COMPATIBILITY MODE
|
|
Condition
|
JP3
|
| »
|
Compatibility mode disabled
|
Open
|
|
|
Compatibility mode enabled
|
Closed
|
|
Note: Compatibility mode should be enabled when the NIC is installed in a system using a Suntac 286 chipset.
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Red
|
Blinking
|
I/O bus activity
|
|
LED1
|
Red
|
Off
|
No I/O bus activity
|
|
LED2
|
Green
|
On
|
Data is being transmitted or received
|
|
LED2
|
Green
|
Blinking
|