NI6210-10BT (VERSION 2)
RACAL INTERLAN, INC.
NI6210-10BT (VERSION 2)
|
NIC Type
|
Ethernet
|
|
Transfer Rate
|
10Mbps
|
|
Data Bus
|
16-bit ISA
|
|
Topology
|
Linear bus
|
|
Wiring Type
|
Unshielded twisted pair
AUI transceiver via DB-15
|
|
Boot ROM
|
Available
|
|
BASE I/O ADDRESS
|
|
Address
|
JP1A
|
JP1B
|
JP1C
|
JP1D
|
|
300h
|
Closed
|
Open
|
Open
|
Open
|
|
320h
|
Open
|
Closed
|
Open
|
Open
|
|
340h
|
Open
|
Open
|
Closed
|
Open
|
|
360h
|
Open
|
Open
|
Open
|
Closed
|
|
BOOT ROM ADDRESS
|
|
Address
|
JP2A
|
JP2B
|
JP2C
|
JP2D
|
JP2E
|
|
D0000h
|
Closed
|
Open
|
Open
|
Open
|
Open
|
|
D4000h
|
Open
|
Closed
|
Open
|
Open
|
Open
|
|
D8000h
|
Open
|
Open
|
Closed
|
Open
|
Open
|
|
DC000h
|
Open
|
Open
|
Open
|
Closed
|
Open
|
|
No Boot ROM
|
Open
|
Open
|
Open
|
Open
|
Closed
|
|
DMA CHANNEL
|
|
Channel
|
JP3A
|
JP3B
|
JP3C
|
JP3D
|
|
DMA0
|
Closed
|
Open
|
Open
|
Open
|
|
DMA3
|
Open
|
Closed
|
Open
|
Open
|
|
DMA5
|
Open
|
Open
|
Closed
|
Open
|
|
DMA6
|
Open
|
Open
|
Open
|
Closed
|
|
INTERRUPT SETTINGS
|
|
IRQ
|
JP4A
|
JP4B
|
JP4C
|
JP4D
|
|
2/9
|
Closed
|
Open
|
Open
|
Open
|
|
5
|
Open
|
Open
|
Open
|
Closed
|
|
12
|
Open
|
Closed
|
Open
|
Open
|
|
15
|
Open
|
Open
|
Closed
|
Open
|
|
CABLE TYPE
|
|
Type
|
SW1
|
|
Unshielded twisted pair
|
Position B
|
|
AUI transceiver via DB-15 port
|
Position A
|
|
LINK INTEGRITY
|
|
Function
|
W18
|
| »
|
Link intergity enabled
|
Pins 1 & 2 closed
|
|
|
Link integrity disabled
|
Pins 2 & 3 closed
|
|
Note: If card is used in a pre-10BaseT cabling network, disable the link integrity function.
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Condition
|
|
On
|
Link integrity exists
|
|
Off
|
Link integrity does not exist
|
|
Note:LED is active only when NIC is used in a 10BaseT network.
|
|