TC6042
THOMAS-CONRAD CORPORATION
TC6042
|
NIC Type
|
ARCnet
|
|
Transfer Rate
|
2.5Mbps
|
|
Data Bus
|
8-bit ISA
|
|
Topology
|
Star
|
|
Wiring Type
|
RG62A/U 93ohm coaxial
|
|
Boot ROM
|
Available
|
|
NODE ADDRESS
|
|
Node
|
SW2/1
|
SW2/2
|
SW2/3
|
SW2/4
|
SW2/5
|
SW2/6
|
SW2/7
|
SW2/8
|
|
0
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
1
|
Off
|
On
|
On
|
On
|
On
|
On
|
On
|
On
|
|
2
|
On
|
Off
|
On
|
On
|
On
|
On
|
On
|
On
|
|
3
|
Off
|
Off
|
On
|
On
|
On
|
On
|
On
|
On
|
|
4
|
On
|
On
|
Off
|
On
|
On
|
On
|
On
|
On
|
|
251
|
Off
|
Off
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
252
|
On
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
253
|
Off
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
254
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
255
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
Note:Node address 0 is used for messaging between nodes and must not be used.
A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1)
|
|
RESPONSE AND RECONFIGURATION TIMEOUT
|
|
Network Cable Length
|
JP6
|
JP7
|
ResponseTime (
m
|
Reconfiguration Time (mS)
|
| »
|
Less than 20,000 feet
|
Open
|
Open
|
74.7
|
840
|
|
|
more than 20,000 feet
|
Closed
|
Open
|
283.4
|
1680
|
|
|
more than 20,000 feet
|
Open
|
Closed
|
561.8
|
1680
|
|
|
more than 20,000 feet
|
Closed
|
Closed
|
1118.6
|
1680
|
|
|
Note : All NICs on the network must have these two jumpers set the same.
|
|
I/O BASE ADDRESS
|
|
Address
|
SW3/1
|
SW3/2
|
SW3/3
|
SW3/4
|
SW3/5
|
SW3/6
|
SW3/7
|
SW3/8
|
| »
|
2E0h
|
On
|
On
|
Off
|
On
|
Off
|
Off
|
Off
|
On
|
|
|
2F0h
|
On
|
On
|
Off
|
On
|
Off
|
Off
|
Off
|
Off
|
|
|
300h
|
On
|
On
|
Off
|
Off
|
On
|
On
|
On
|
On
|
|
|
310h
|
On
|
On
|
Off
|
Off
|
On
|
On
|
On
|
Off
|
|
|
320h
|
On
|
On
|
Off
|
Off
|
On
|
On
|
Off
|
On
|
|
|
330h
|
On
|
On
|
Off
|
Off
|
On
|
On
|
Off
|
Off
|
|
|
340h
|
On
|
On
|
Off
|
Off
|
On
|
Off
|
On
|
On
|
|
|
350h
|
On
|
On
|
Off
|
Off
|
On
|
Off
|
On
|
Off
|
|
|
360h
|
On
|
On
|
Off
|
Off
|
On
|
Off
|
Off
|
On
|
|
|
370h
|
On
|
On
|
Off
|
Off
|
On
|
Off
|
Off
|
Off
|
|
|
380h
|
On
|
On
|
Off
|
Off
|
Off
|
On
|
On
|
On
|
|
|
390h
|
On
|
On
|
Off
|
Off
|
Off
|
On
|
On
|
Off
|
|
|
3A0h
|
On
|
On
|
Off
|
Off
|
Off
|
On
|
Off
|
On
|
|
|
3B0h
|
On
|
On
|
Off
|
Off
|
Off
|
On
|
Off
|
Off
|
|
|
3C0h
|
On
|
On
|
Off
|
Off
|
Off
|
Off
|
On
|
On
|
|
|
3D0h
|
On
|
On
|
Off
|
Off
|
Off
|
Off
|
On
|
Off
|
|
|
3E0h
|
On
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
On
|
|
|
3F0h
|
On
|
On
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
BASE MEMORY ADDRESS
|
|
Address
|
SW1/1
|
SW1/2
|
SW1/3
|
SW1/4
|
SW1/5
|
SW1/6
|
SW1/7
|
| »
|
D000h
|
Off
|
Off
|
On
|
Off
|
On
|
On
|
On
|
|
|
E000h
|
Off
|
Off
|
Off
|
On
|
On
|
On
|
On
|
|
|
C400h
|
Off
|
Off
|
On
|
On
|
On
|
Off
|
On
|
|
|
C800h
|
Off
|
Off
|
On
|
On
|
Off
|
On
|
On
|
|
|
CC00h
|
Off
|
Off
|
On
|
On
|
Off
|
Off
|
On
|
|
|
D400h
|
Off
|
Off
|
On
|
Off
|
On
|
Off
|
On
|
|
|
D800h
|
Off
|
Off
|
On
|
Off
|
Off
|
On
|
On
|
|
|
DC00h
|
Off
|
Off
|
On
|
Off
|
Off
|
Off
|
On
|
|
INTERRUPT REQUEST
|
|
IRQ
|
JP1
|
JP2
|
JP3
|
JP4
|
JP5
|
| »
|
2
|
Open
|
Open
|
Open
|
Open
|
Closed
|
|
|
3
|
Closed
|
Open
|
Open
|
Open
|
Open
|
|
|
4
|
Open
|
Closed
|
Open
|
Open
|
Open
|
|
|
5
|
Open
|
Open
|
Closed
|
Open
|
Open
|
|
|
7
|
Open
|
Open
|
Open
|
Closed
|
Open
|
|
COMPATIBILITY MODE
|
|
Mode
|
SW1/8
|
| »
|
Enhanced mode
|
On
|
|
|
Compatible mode
|
Off
|
|
Note: Enhanced mode optimizes performance and minimizes conflicts of your hardware, by using a Thomas-Conrad ARCNET driver. It is also not necessary to set the I/O address. In compatible mode the adapter can use most existing ARCNET drivers.
|
|