E-FRL-MC04, E-FRL-MC04(SM), E-FRL-MC04(L)
TRANSITION NETWORKS
E-FRL-MC04, E-FRL-MC04(SM), E-FRL-MC04(L)
|
Card Type
|
Ethernet Transceiver
|
|
NIC Type
|
Ethernet
|
|
Maximum Onboard Memory
|
Unidentified
|
|
Boot ROM
|
Not available
|
|
Network Transfer Rate
|
10Mbps
|
|
Topology
|
Linear Bus, Star
|
|
Wiring Type
|
AUI transceiver via DB-15 port, Fiber optic cable
|
|
Data Bus
|
External
|
|
CONNECTIONS
|
|
Function
|
Label
|
Function
|
Label
|
|
AUI transceiver via DB-15
|
CN1
|
Fiber optic - ST transmit
|
CN3
|
|
Fiber optic - ST receive
|
CN3
|
|
|
|
USER CONFIGURABLE SETTINGS
|
|
Function
|
Label
|
Position
|
|
SQE enabled
|
SW1
|
On
|
|
SQE disabled
|
SW1
|
Off
|
|
Full duplex mode enabled
|
SW2
|
On
|
|
Half duplex mode enabled
|
SW2
|
Off
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Color
|
Status
|
Condition
|
|
LED1
|
Red
|
On
|
Jabber detected on network
|
|
LED1
|
Red
|
Off
|
No jabber detected on network
|
|
LED2
|
Red
|
Blinking/On
|
Collision detected on network
|
|
LED2
|
Red
|
Off
|
No collision detected on network
|
|
LED3
|
Green
|
Blinking/On
|
Data is being transmitted
|
|
LED3
|
Green
|
Off
|
Data is not being transmitted
|
|
LED4
|
Green
|
Blinking/On
|
Data is being received
|
|
LED4
|
Green
|
Off
|
Data is not being received
|
|
LED5
|
Green
|
On
|
Network connection is good
|
|
LED5
|
Green
|
Off
|
Network connection is broken
|
|
LED6
|
Green
|
On
|
Receiving power
|
|
LED6
|
Green
|
Off
|
Not receiving power
|
|
MISCELLANEOUS TECHNICAL NOTES
|
|
The E-FRL-MC04 uses 850mn multi-mode fiber cable, the E-FRL-MC04(SM) uses 1300mn single-mode fiber cable, and the E-FRL-MC04(L) uses 1300mn multi-mode fiber cable.
|
|