USER CONFIGURABLE SETTINGS
|
|
Setting
|
Label
|
Position
|
| »
|
Factory configured - do not alter
|
SW1/1
|
Reserved
|
| »
|
Factory configured - do not alter
|
SW1/2
|
Reserved
|
| »
|
Factory configured - do not alter
|
SW1/3
|
Reserved
|
| »
|
SCSI 2 mode enable
|
SW1/4
|
On
|
|
|
SCSI 1 mode enabled
|
SW1/4
|
Off
|
| »
|
Parity check disabled
|
SW1/5
|
Off
|
|
|
Parity check enabled
|
SW1/5
|
On
|
| »
|
DDS pass-through mode disabled
|
SW1/6
|
Off
|
|
|
DDS pass-through mode enabled
|
SW1/6
|
On
|
| »
|
Factory configured - do not alter
|
SW1/7
|
Reserved
|
| »
|
Power on self test mode disabled
|
SW1/8
|
Off
|
|
|
Power on self test mode enabled
|
SW1/8
|
On
|
|
|
Drive mounted in horizontal position
|
SW2/1
|
Off
|
|
|
Drive mounted in vertical position
|
SW2/1
|
On
|
|
|
Automatic insertion of first cartridge enabled
|
SW2/2
|
On
|
|
|
Automatic insertion of first cartridge disabled
|
SW2/2
|
Off
|
| »
|
Factory configured - do not alter
|
SW2/3
|
Reserved
|
| »
|
Factory configured - do not alter
|
SW2/4
|
Reserved
|
|
|
Continuous cycle cartridge loading enabled
|
SW3/3
|
On
|
|
|
Continuous cycle cartridge loading disabled
|
SW3/3
|
Off
|
|
|
High intensity display
|
SW3/4
|
On
|
|
|
Normal intensity display
|
SW3/4
|
Off
|
|
|
Self-test sequence enabled
|
SW3/5
|
On
|
|
|
Self-test sequence disabled
|
SW3/5
|
Off
|
| »
|
Factory configured - do not alter
|
SW3/6
|
Reserved
|
| »
|
Factory configured - do not alter
|
SW3/7
|
Reserved
|
| »
|
Terminator power disabled
|
JP2
|
Open
|
|
|
Terminator power enabled
|
JP2
|
Closed
|