Vulnerability WatchGuard SOHO Firewall Affected WatchGuard SOHO Firewall 2.2 and prior Description Following is based on Steve Fallin post. On September 13, ISS advised WatchGuard of three suspected vulnerabilities in older versions (prior to 2.2) of software running on WatchGuard's SOHO Firebox product. They later reported a fourth vulnerability. The vulnerabilities are: 1. Inappropriately accessing configuration files using the HTTP configuration server (affects releases prior to 2.1.3) ISS found the SOHO responded to HTTP requests (such as 192.168.111.1/secret.dat to access the file secret.dat). The SOHO only honors HTTP requests from inside the trusted LAN network. Outsiders could not exploit this vulnerability. This vulnerability was verified and corrected in Release 2.1.3. 2. A possible buffer overflow - arbitrary code might be executed by applying an excessively long HTTP GET request (affects releases prior to 2.1.3) The way memory is architected in the SOHO, they do not believe that this exploit could be used to run arbitrary code. They believe that the potential damage caused by this attack would be a Denial of Service by crashing the administration server, requiring a reboot. Again, this vulnerability could only be exploited inside the trusted LAN. 3. DoS could be induced by flooding the SOHO with fragmented packets (affects release 1.6.0 and previous) SOHO was able to reproduce this problem with version 1.6.0. 1.6.0 stopped shipping in early August. The issue does not exist in any 2.x release. All LiveSecurity subscribers would have updated their SOHOs to a 2.x release long before this vulnerability was reported. 4. SOHO password can be reset using a POST operation without authentication (affects releases prior to 2.2.0) The SOHO only honors HTTP requests from inside the trusted LAN network. Outsiders could not exploit this vulnerability. This vulnerability was verified and corrected in Release 2.2. Release 2.2 was broadcast to all current subscribers in mid-November and has been available on our Web site since then. Solution All the items were addressed in previous releases of the software and are no longer issues. The currently shipping version of the SOHO software is 2.2.1. Current LiveSecurity subscribers are automatically sent new versions of software as the software becomes available. In addition, the most current version of the software is always posted on our Web site. All LiveSecurity subscribers should be running the most current version of the software to maintain the highest level of protection.