AT&T 1710 NOTES: This is a dual NAM unit. The ESN prefix is 132 decimal & 84 hex (Hitachi). A T & T west: 213-726-5360, east: 1-800-222-5111 NAM programing: 1. Select the NAM to be programed by entering FCN 6 2 N # FCN. Where "N" is the NAM number 1 or 2 (ignore the error tone). 2. Enter FCN 6 2 6 RCL to enter programing mode. (626 spells NAM) 3. The DOWN key stores each entry and increments the step number. 4. At any time press FCN 6 2 6 STO to complete and exit programing. PROGRAMING DATA: STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION 01 0000 - 32767 SIDH SYSTEM ID 02 0 OR 1 LOCAL LOCAL USE MARK 03 0 OR 1 MINMK MIN MARK 04 0 OR 1 A-B A/B SWITCH MARK 05 0 OR 1 NROAM ROAM INHIBIT 06 10 DIGITS AREA/TEL MIN (AREA CODE & PHONE NUMBER) 07 2 DIGITS SCM STATION CLASS MARK 08 333 OR 334 IPCH INITIAL PAGING CHANNEL 09 2 DIGITS OLC ACCESS OVERLOAD 10 0 OR 1 SYS PREFERRED SYSTEM 11 2 DIGITS GIM GROUP ID (10 FOR USA) 12 3 DIGITS LCODE LOCK CODE 13 0 OR 1 DTMF CONTINUOUS DTMF 14 0 OR 1 HF HANDS FREE NOTE: 1 enables, 0 disables in all single digit entries. LOCK: Press and hold LOCK for 1.5 seconds. UNLOCK: Enter three digit code. SYSTEM SELECT: F 9 */down to scroll, STO to store.