CM Telecom AR3800 Detailed Programming

-------------------------------------------------------------------------------
                 CMTELECOM AR 3800 mobile/transportable
-------------------------------------------------------------------------------
                NAM Type:  EEPROM
            Manufacturer:  CMTELECOM
          ESN Prefix DEC:  153
                     HEX:  99
ESN, Serial Number Match:  yes

    Programming Sequence:
                           Power ON
                           Lock Phone: FUNC + 1 + 1 (press 1 until "F-Lock"
                            displays) + SND
          Enter Password:  * + 5965 ("Conf 3800" will display, else enter
                            Password * + 0188)
                           Press VOL UP or DOWN keys to increment steps
                           RCL + 2 digit step # to reach specific parameters
                           SND must be pressed to save info after each step
                           To store complete NAM info press END

     Step            # of digits
      1 Mobile Number 1:  10    XXX-XXX-XXXX + SND + VOL UP
          2 System ID 1:  5     XXXXX + SND + VOL UP
    3 Init. paging ch 1:  3     333 or 334 + SND + VOL UP
    4 Access Overload 1:  2     XX + SND + VOL UP
           5 Group ID 1:  2     XX + SND + VOL UP
          6 Local Use 1:  1    1(SND to toggle) + VOL UP
      7 System Select 1:  1     0 = 0 + SND + VOL UP
                                1 = BA + SND + VOL UP
                                2 = A only + SND + VOL UP
                                3 = B only + SND + VOL UP
                                4 = Home + SND + VOL UP
         8,9 Not Used  (VOL UP)
     10 Mobile Number 2:  10    XXX-XXX-XXXX + SND + VOL UP
         11 System ID 2:  5     XXXXX + SND + VOL UP
  12 Init pagin Channel:  3     333 or 334 + SND + VOL UP
   13 Access Overload 2:  2     XX + SND + VOL UP
          14 Group ID 2:  2     XX + SND + VOL UP
         15 Local use 2:  1     1 (SND to toggle) + VOL UP
     16 System Select 2:  1     0 = AB + SND + VOL UP
                                1 = BA + SND + VOL UP
                                2 = A Only + SND + VOL UP
                                3 = B Only + SND + VOL UP
                                4 = Home + SND + VOL UP
          17 Future Use:  1     0 + SND + VOL UP
          18 Power Save:  1     0(Dis) or 1(Enable) + SND + VOL UP
           19 System ID:  5     XXXXX + SND + VOL UP
       20 Prog Password:  5     Leave at Factory Set Number + VOL UP

             Horn Alert:  FUNC + 4 + SND
        New Unlock Code:  NAM
         System Seltect:  FUNC + (ALPHA to scroll)
                          PrefA AB
                          PrefB BA
                          Only A
                          Only B
                          Only H Home

SND to enter selection
CLR to exit