UNIDEN 5000 and 6000 GTS Portable
NAM Type: EEPROM
Manufacturer: UNIDEN
Programmer: Program or Service Handset with CP 505 Adaptor
ESN Prefix DEC: 172
HEX: AC
ESN, S/N Match Required: Yes
Stamped Model Number: 5000 or 6000 GTS
Number of Channels: 832
Programming Sequence: Power Off
Remove Battery and install CP505 or CP505A adaptor
Connect CP505(A) to power supply or to CP
504 battery eliminator per adaptor instructions
Connect Program Handset to CP 505(A) adaptor
White Handset (CP-010): Turn Power Switch On while holding *
and # continue holding * and # for two seconds
Blue Handset(CP-210): Turn Power Switch On
Press SELECT + 2 + SEND
Both Handsets: Enter step number, then data for individual
parameter
Press STO to enter data for each step
Increment by pressing next step number
To review parameters press: RCL + Step number + STO (to exit)
To select Alternate NAM, Press 1 + STO + 90 (NAM 1)
or 2 + STO + 90 (NAM 2)
Press SEND to write NAM information
PASS will appear in display if data is valid
Step # of Digits
0 System ID: 5 XXXXX + STO
1 Local Use: 1 (0 or 1) + STO
2 MIN Opt: 1 (0 or 1) + STO
3 Mobile Number: 10 XXX-XXX-XXXX + STO
4 Initial Page Channel: 3 (333 or 334) + STO
5 Access Overload: 2 XX + STO
6 Preferred System: 1 [0 (B) or 1 (A)] + STO
7 Group ID: 2 XX + STO
8 Lock code (1): 4 XXXX + STO
9 Options F5 DTMF
Duration: 1 0 - Continuous
1 - 100 ms
Press STO to program phone
New Unlock Code: RCL + 70 + Current 4 digit Unlock code
+ new 4 digit Unlock code
System Select: X + STO + 8 + 8
X=1 A only
X=2 B Only
X=3 Home
X=4 Standard AB or BA
X=5 Inverted BA or AB
TUCoPS is optimized to look best in Firefox® on a widescreen monitor (1440x900 or better).