|
NAM Programming (Reprogramming) Instructions For 30+ Cellular Telephones <--Part 1--> Presented By: /E/D/I/S/O/N///C/A/R/T/E/R/ Of NETWORK 23 24 HOURS 1200/2400 BAUD (402) 467-2474 ----------------------------------------------------------------------------- PLEASE NOTE: Area specific numbers contained within these programming instructions may not be accurate for your cellular area. ----------------------------------------------------------------------------- Programming Instructions for: DIAMONDTEL MESA90X HANDHELD ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - PRESS FCN 7 ENTER 4 DIGIT SECURITY CODE ENTER NEW 3 DIGIT UNLOCK CODE PRESS CLR PWR up unit Press "END" and hold within 10 seconds of pwr up Enter "5132920" Release END key. 0 SEND DUAL NO XXXXXXXXXX SEND NO1 _ _ _ _ _ SEND SID1 1 SEND LU1 1 SEND EX1 334 SEND IPCH1 07 SEND ACCOLC1 0 SEND PREF1 10 SEND GIM1 0 SEND RI1 1 SEND DTX1 1 SEND AR1 1234 SEND SEC 1 SEND EE 1 SEND C TONE 0 SEND AL 0 SEND BO 1 SEND BEEP TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME TO RESET NAM FROM THE LIMIT OF 3 PROGRAM ATTEMPTS PWR up unit Press "END" and hold within 10 seconds of pwr up TO RESET NAM OF MESA 90 HANDHELD USE THE CODE "6972814" Programming Instructions for: DIAMONDTEL MESA99X HANDHELD ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - PRESS FCN 7 ENTER 4 DIGIT SECURITY CODE ENTER NEW 3 DIGIT UNLOCK CODE PRESS CLR PWR up unit Press "END" and hold within 10 seconds of pwr up Enter "5132920" Release END key. 0 SEND DUAL NO XXXXXXXXXX SEND NO1 _ _ _ _ _ SEND SID1 1 SEND LU1 1 SEND MIN MARK1 334 SEND IPCH1 07 SEND ACCOLC1 10 SEND GIM1 0 SEND RI1 0 SEND DTX1 0 SEND AR1 1234 SEND SEC 1 SEND CONTINUE D.T.M.F. 0 SEND AUTO LOCK 0 SEND BOOSTER TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME Programming Instructions for: GATEWAY CP 900 HANDHELD USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - CURRENT UNLOCK CODE CAN NOT BE SEEN AND MUST BE KNOWN TO CHANGE THE CURRENT UNLOCK CODE. PRESS MENU ENTER 03 ENTER CURRENT 4 DIGIT SECURITY CODE ENTER NEW 4 DIGIT SECURITY CODE PHONE WILL AUTO EXIT TO READY ACTION TO STORE DISPLAY PRESS MENU 99 ENTR SCRTY CODE(FCTRY PRST IS 9999) PROGRAM NAM _ _ _ _ _ SEND SID XXXXXXXXXX SEND PHONE NUMBER 0334 SEND IPC 07 SEND ACCOL 10 SEND GIM 1 SEND MOBILE I.D. NUMBER 1 SEND LOCAL USE MARK 2 SEND SYSTEM SELECT (B) UPON PRESSING SEND THE PHONE WILL CYCLE TO WAIT AND THEN RETURN TO THE READY MODE. TO DISPLAY THE NEW PHONE NUMBER: PRESS RCL 00 Programming Instructions for: GENERAL ELECTRIC MINI II ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - PRESS FCN 7 ENTER 4 DIGIT SECURITY CODE ENTER NEW 3 DIGIT UNLOCK CODE PRESS CLR PWR up unit Press and hold END key within 10 seconds of pwr up Enter "6282905" Release END key 0 Press SEND DUAL NO XXXXXXXXXX Press SEND NO1 _ _ _ _ _ Press SEND SID1 1 Press SEND LU1 1 Press SEND EX1 0334 Press SEND IPCH1 07 Press SEND ACCOLC1 0 Press SEND PREF1 10 Press SEND GIM1 0 Press SEND RI1 1 Press SEND DTX1 1 Press SEND AR1 1234 Press SEND SEC 1 Press SEND EE 1 Press SEND C DTMF 0 Press SEND AL 0 Press SEND BEEP 0 Press SEND BO TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME Programming Instructions for: GENERAL ELECTRIC MINI ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE FOLLOW THE INSTRUCTIONS THAT FOLLOW PWR up unit Press and hold CL key within 10 seconds of pwr up 0Enter "7591122" Release CL key XXXXXXXXXX PRESS SEND MIN 123 PRESS SEND UNLOCK _ _ _ _ _ PRESS SEND SID 1 PRESS SEND LU 1 PRESS SEND MIN MARK 334 PRESS SEND IPCH 07 PRESS SEND ACCOLC 0 PRESS SEND PS 10 PRESS SEND GIM 1 PRESS SEND EE 0 PRESS SEND BOOSTER 1 PRESS SEND AR TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME Programming Instructions for: MITSUBISHI 800 ACTION TO STORE DISPLAY PWR up unit Press and Hold STO within 10 Seconds of pwr up Enter "5474432" Release STO 0 Press SEND dUAL XXXXXXXXXX Press SEND NO1 _ _ _ _ _ Press SEND SId1 1 Press SEND LU1 0 Press SEND MIN Mark 0334 Press SEND IPCH 07 Press SEND ACCOLC 0 Press SEND PS1 10 Press SEND GI1 1234 Press SEND SECUrity 1 Press SEND EE 0 Press SEND dt 1 Press SEND HF 0 Press SEND InHIbit 1 Press SEND C tOnE 0 Press SEND SyS A/B 0 Press SEND dUAL HS 0 Press SEND InHibit Ld TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME Programming Instructions for: MITSUBISHI 900 ACTION TO STORE DISPLAY PWR up unit Press and Hold END key within 10 seconds of pwr up Enter "6972814" Release END key 0 Press SEND DUAL NO XXXXXXXXXX Press SEND NO1 _ _ _ _ _ Press SEND SID1 1 Press SEND LU1 0 Press SEND EX1 0334 Press SEND IPCH1 07 Press SEND ACCOLC1 0 Press SEND PREF1 10 Press SEND GIM1 0 Press SEND RI1 1 Press SEND DTX1 1 Press SEND AR1 1234 Press SEND SEC 1 Press SEND EE 1 Press SEND C DTMF 0 Press SEND AL 0 Press SEND BO 1 Press SEND BEEP TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME TO ENTER TEST MODE HOLD END ON PWR UP-CODE 0944635 Programming Instructions for: MOTOROLA 8000H ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED IN STEP 9 OF THE PROGRAMMING MODE PWR up unit Enter STORE #123456123456 RCL If the phone is fresh from factory then Enter STORE #000000000000 RCL If the phone is used or already programmed then Enter STORE #123456123456 RCL DISPLAY WILL SHOW 01 PRESS * _ _ _ _ _ * 02 (SID) XXX * 03 (Area Code) XXX XXXX * 04 (Phone #) 14 * 05 07 * 06 00 * 07 123456 * 08 123 * 09 334 * 10 010100 * 11 000 * PRESS * TO REVIEW ENTRIES TO BURN NAM: PRESS SEND WHILE 01,02,03, ETC. IS DISPLAYED SET TO SCAN B MODE BY : RCL * : PRESS * UNTIL SCAN B MODE SHOWS then: press store Programming Instructions for: MOTOROLA ULTRA CLASSIC HANDHELD ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THE UNLOCK CODE IS PROGRAMMED IN STEP 8 OF THE PROGRAMMING MODE FOR NEW PHONE: Press FCN, 0 + Security code entered twice (Factory preset is 000000), RCL The message 01 will appear in the display to confirm programming mode. Press * 01 Press * 1) _ _ _ _ _ Press * 02 Press * 2) XXX Press * 03 Press * 3) XXX XXXX Press * 04 Press * 4) 14 Press * 05 Press * 5) 07 Press * 06 Press * 6) 10 Press * 07 Press * 7) 123456 Press * 08 Press * 8) 123 Press * 09 Press * 9) 0334 Press * 10 Press * 10) 010101 Press * 11 Press * 11) 101 Press * 12 Press * Review entries by pressing "*" repeatedly. Press SEND to program phone. Programming Instructions for: NEC P300 ACTION TO STORE DISPLAY THESE INSTRUCTIONS FOR SERIAL NUMBERS AFTER 135-839601 Insert NAM Programming Adapter (NECAM #41-2019) into plug connector on P300 phone bottom. PWR On RCL # 0 1 to enter test mode. Phone will display shaded blocks. RCL # 7 6 to select NAM. Phone will show 76- Press 0 # to program NAM 1. (NAM 1=0,NAM 2=1,NAM 3=2,NAM 4=3) RCL # 7 1 to enter programming mode. XXXXXXXXXX PRESS # MIN 1234 PRESS # LOCK CODE _ _ _ _ _ PRESS # SID 10 PRESS # GROUP I.D. 0334 PRESS # INITIAL PAGING CH 0 PRESS # SYSTEM SELECT (1=A) 07 PRESS # ACCOLC 1 PRESS # MIN MARK 1 1 PRESS # LOCAL USE 911 PRESS # EMERGENCY NO. Press Clr (and hold) to exit programming and return to TEST MODE. Press RCL # 0 2 to burn and exit to standby. THESE INSTRUCTIONS FOR SERIAL NUMBERS PRIOR TO 135-839601 Insert NAM Programming Cable (41-2019) PWR on RCL # 7 6 to enter TEST MODE Press 0 # to select NAM. RCL # 7 1 You are now in Programming Mode. Enter NAM info as above. Press and hold CLR to exit. Pwr down. Programming Instructions for: NEC P9100 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE FOLLOW THE INSTRUCTIONS THAT FOLLOW Make sure NAM battery is fully charged before attempting programming Switch power on Press RCL #01 display will then show shaded blocks For a USED phone - to clear nam and accumulated call timer Press RCL #39 To program NAM1 Press RCL #760# To enter programming mode Press RCL #71 XXXXXXXXXX Press # MIN 1234 Press # Lock Code _ _ _ _ _ Press # SYS. I.D. 10 Press # G.I. Mark 0334 Press # First Paging Channel 0 Press # System Select 07 Press # ACCOLC 0 Press # MIN Mark 1 Press # Local Use TO EXIT PROGRAM MODE AT THIS TIME PRESS CLR AND HOLD DISPLAY WILL SHOW TEST MODE TO EXIT TEXT MODE PRESS RCL#02 IF THE MEMORY IS CLEARED VIA RCL #39 DURING THE PROGRAMMING THEN THE PHONE WILL AUTOMATICALLY ENTER FULL-LOCK AFTER EXITING THE TEST MODE TO UNLOCK: FCN #XXXX(4 DIGIT LOCK CODE FOR LAST NAM PROGRAMMED). Programming Instructions for: NOKIA P-30 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - PRESS SEL 7 UNLCODE APPEARS ON THE DISPLAY ENTER 5 DIGIT SECURITY CODE AND THE CURRENT UNLOCK CODE APPEARS IN THE DISPLAY PRESS CLR AND ENTER THE NEW FOUR DIGIT UNLOCK CODE PRESS SEL TO STORE THE NEW CODE - NOTE: IF YOU DON'T PRESS SEL WITHIN FIVE SECONDS THE DISPLAY WILL CLEAR AND CANCEL THE FUNCTION PWR up unit Enter *17*2001*12345* HO-Id must appear on display Press SEL to view current value Display will be one step behind TO STORE instructions _ _ _ _ _ Press SEL ACCESS (SID) 1 Press SEL LOCAL 1 Press SEL PhonE n XXXXXXXXXX Press SEL CLASS 10 Press SEL PAGE ch 334 Press SEL O-LOAd 07 Press SEL GrouP 10 Press SEL SEC 12345 Press SEL AUTO EXIT PROGRAM MODE TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END" WHEN THE SEL KEY IS PRESSED FOLLOWING THE LAST PARAMETER VALUE, THE PHONE WILL AUTOMATICALLY EXIT THE NAM PROGRAMMING MODE AND RETURN TO NORMAL OPERATION Programming Instructions for: NOVATEL PTR800 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE FOLLOW THE INSTRUCTIONS THAT FOLLOW PWR up unit Press FCN Press FCN again Enter *626776* Display will show CMT REV and a date code - Press Volume Up Display will show NAM SELECT1 Press Volume Up _ _ _ _ _ PRESS # PRESS VOLUME UP SIDH PRESS VOLUME UP SCM XXXXXXXXXX PRESS # PRESS VOLUME UP MIN 0333 PRESS # PRESS VOLUME UP IDCCA 0334 PRESS # PRESS VOLUME UP IDCCB 0334 PRESS # PRESS VOLUME UP IPCH 07 PRESS # PRESS VOLUME UP ACCOLC 10 PRESS # PRESS VOLUME UP GIM 123 PRESS # PRESS VOLUME UP LOCK A 456 PRESS # PRESS VOLUME UP LOCK B 1 PRESS # PRESS VOLUME UP OPTION LC 1 PRESS # PRESS VOLUME UP OPTION EX 0 PRESS # PRESS VOLUME UP OPTION PS 0 PRESS # PRESS VOLUME UP OPTION NSC 1 PRESS # PRESS VOLUME UP OPTION EE 1 PRESS # PRESS VOLUME UP OPTION REP 0 PRESS # PRESS VOLUME UP OPTION HA 0 PRESS # PRESS VOLUME UP OPTION HF 0 PRESS # PRESS VOLUME UP OPTION F1 0 PRESS # PRESS VOLUME UP OPTION F2 0 PRESS # PRESS VOLUME UP OPTION F3 0 PRESS # PRESS VOLUME UP OPTION F4 TO EXIT PROGRAMMING MODE AT ANY TIME PRESS FCN END FCN FCN *6462257* WILL CLEAR THE NAM IF IT HAS BEEN PROGRAMMED MORE THAN 3 TIMES OR IF THE NEED EXISTS TO CLEAR THE MEMORY Programming Instructions for: NOVATEL PTR825 ACTION TO STORE DISPLAY PWR up unit Press FCN Press FCN again Enter *697201* Display will show CMT REV 972 105 Press Volume Up 1 PRESS # VOL UP NAM SELECT 1 _ _ _ _ _ PRESS # VOL UP SIDH 10 PRESS VOL UP SCM XXXXXXXXXX PRESS # VOL UP MIN 0333 PRESS VOL UP IDCCA 0334 PRESS VOL UP IDCCB 0334 PRESS # VOL UP IPCH 07 PRESS # VOL UP ACCOLC 10 PRESS # VOL UP GIM 123 PRESS # VOL UP LOCK A 123 PRESS # VOL UP LOCK B 1 PRESS # VOL UP LC 1 PRESS # VOL UP OPTION EX 0 PRESS # VOL UP PS - PREF SYSTEM 0 PRESS VOL UP OPTION NSC 1 PRESS # VOL UP OPTION EE-END TO END 1 PRESS # VOL UP OPTION REP 0 PRESS # VOL UP HORN ALERT 0 PRESS # VOL UP HANDS FREE 0 PRESS # VOL UP OPTION F1 0 PRESS # VOL UP OPTION F2 0 PRESS # VOL UP OPTION F3 1 PRESS # VOL UP OPTION F4 AIR RND UP 0 PRESS # VOL UP OPTION F5 FUTURE USE 0 PRESS # VOL UP OPTION F6 FUTURE USE 0 PRESS # VOL UP OPTION F7 FUTURE USE Programming will now wrap to beginning SIDH display. Press VOL UP to review entries Programming Instructions for: OKI HANDHELD MODEL # 750 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE Pwr up unit Press (*) and (#) simultaneously Enter 10 digit Sec Code as follows: *12345678# What follows can be done only once! The display "Enter NEW PW-Sto" Enter 0123456789 then press STORE Pwr unit down. Pwr up unit Press MENU and RCL simultaneously Enter 0123456789 Software Version and ESN Number in HEX Clears in 2 secs. Spd Dial Mem Clear Press 0 Press STO Def Data Reset Press 0 Press STO NAM 1 Mode Own #111 111-1111 XXX XXX XXXX Press STO Vol Up Security 123456 Press STO Vol Up OPTION 1100 Press STO Vol Up SCM 1010 Press STO Vol Up GIM 10 Press STO Vol Up Unlock # 1234 Press STO Vol Up ACCOLC # 07 Press STO Vol Up IPCH NO. 0334 Press STO Vol Up _ _ _ _ _ Press STO Vol Up System ID: At this time you may exit the programming mode by pressing CLR to bypass the other NAM modules. Programming Instructions for: OKI HANDHELD MODEL # 900 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE Pwr up unit Press RCL and MENU simultaneously Enter 10 digit Sec Code as follows: *12345678# What follows can be done only once! The display "Enter NEW PW-Sto" Enter 0123456789 then press STORE. The display "Re-Enter New PW-Sto" Enter 0123456789 then press STORE to enter Programming Mode. IF You don't wish to keep the new password then Pwr unit down. Software Version and ESN Number in HEX Clears in 2 secs. Spd Dial Mem Clear Press * Press STO SPD DIAL MEM CLEAR Press * Press STO DEFAULT DATA CLEAR NAM 1 Mode Own #111 111-1111 XXX XXX XXXX Press STO Vol Up MIN 123456 Press STO Vol Up SECURITY _ _ _ _ _ Press STO Vol Up SYSTEM ID: 0334 Press STO Vol Up IPCH 07 Press STO Vol Up ACCOLC # 15 Press STO Vol Up GROUP I.D. 1234 Press STO Vol Up UNLOCK CODE 1010 Press STO Vol Up STATION CLASS 1110 Press STO Vol Up OPTION At this time you may exit the programming mode by pressing CLR to bypass the other NAM modules. Programming Instructions for: PANASONIC EB3500 Charged Battery and Nam Adaptor are needed. ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE *0000# to enter program mode *1 Press SND NAM 1 MODE _ _ _ _ _ Press STO 01 SIDH XXXXXXXXXX Press STO 02 OWNDL 0 Press STO 03 PRESYS 334 Press STO 04 IPCH 07 Press STO 05 ACCOLC 10 Press STO 06 GIM 00 Press STO 07 DLMT 10 Press STO 08 SCM 911 Press STO 09 SPDL 1234 Press STO 10 LOCK 1 1 0 1 1 0 0 0 Press STO 11 FCN 1 0 0 0 1 0 1 0 0 Press STO 12 FCN 2 1 1 1 1 0 1 1 1 Press STO 13 FCN 3 STO ** END to program phone Programming Instructions for: COLT TRANSPORTABLE ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE FOLLOW THE INSTRUCTIONS THAT FOLLOW Phone must be locked, to accomplish: press FUNC 5 Enter: FUNC #626# FUNC The software revision date will be shown. Press SEND This will advance phone through memory locations. E.S.N. will be displayed, press SEND again. XXX Press SEND AREA CODE XXX XXXX Press SEND PHONE NUMBER _ _ _ _ _ Press SEND SYSTEM ID 07 Press SEND ACCOLC 10 Press SEND GIM 1 Press SEND LOCAL USE MARK 1 Press SEND MIN MARK (MOBILE ID) 123 Press SEND LOCK CODE 0 Press SEND AUTOMATIC LOCK 123 Press SEND CALL RESTRICTION 12 Press SEND CALL COUNTER RESET 1 Press SEND ENABLE HANDSFREE 0 Press SEND DISABLE HORN ALERT 0 Press SEND HA TURN OFF TIME 12 Press SEND TOTAL AIRTIME RESET TO REVIEW PROGRAMMING AT THIS TIME PRESS SEND. TO EXIT PROGRAMMING AND STORE DATA AT ANY TIME PRESS END FUNC END - WAKE UP WILL SOUND, PHONE WILL BE LOCKED ENTER UNLOCK CODE- 123 SYSTEM PREFERENCE MUST BE KEYPAD SELECTED! PRESS FUNC 7 FOR "A" NON W/L OR PRESS FUNC 8 FOR "B" W/L SYS. Programming Instructions for: DIAMONDTEL MESA 55 TRANSPORTABLE ACTION TO STORE DISPLAY PWR up unit Press "CL" and hold within 10 seconds of pwr up Enter "1951426" Current Mobile I.D. will display XXXXXXXXXX Press SEND MIN 123 Press SEND 1 SECURITY _ _ _ _ _ Press SEND 2 SID 1 Press SEND 3 LU 1 Press SEND 4 MIN MARK 334 Press SEND 5 IPCH 07 Press SEND 6 ACCOLC 0 Press SEND 7 PREF SYS 10 Press SEND 8 GIM 1 Press SEND 9 EE 1 Press SEND 10 ENBL HANDSFREE 0 Press SEND 11 RI 04 Press SEND 12 AUX 1 07 Press SEND 13 AUX 2 Phone automatically returns to show the 10 digits MIN number at this time and to indicate that the NAM has been programmed. The END key should be pressed to burn the NAM. Programming Instructions for: DIAMONDTEL MESA95 TRANSPORTABLE ACTION TO STORE DISPLAY PWR up unit Press and hold Clr within 10 Seconds of pwr up Enter "1951426" Release Clr 0 Press SEND duaAL no XXXXXXXXXX Press SEND no1 _ _ _ _ _ Press SEND SId1 1 Press SEND LU1 1 Press SEND E1 334 Press SEND IPCH1 07 Press SEND ACCOLC1 0 Press SEND PS1 10 Press SEND GI1 5 Press SEND t InC1 1234 Press SEND SECUrIty 1 Press SEND EE 0 Press SEND dt 0 Press SEND HF 0 Press SEND InHIbIt 1 Press SEND Ctone 0 Press SEND dIS CU 0 Press SEND dIS IGn SEnSE 0 Press SEND DUAL HS TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME TO RESET NAM FROM THE LIMIT OF 3 PROGRAM ATTEMPTS FOLLOW THE BLOCK OF INSTRUCTIONS AT TOP USING "8291112" W/CLR TO RESET NAM OF MESA 90 HANDHELD USE THE CODE "6972814" Programming Instructions for: FUJITSU MOBILE PHONE ACTION TO STORE DISPLAY PWR up unit Unit must be locked to program. To lock press F+LOCK PWR down unit. PWR up unit. Within 10 seconds press #626#7764726 (#NAM#PROGRAM) A continuous tone will be heard for 7 seconds. PRESS AND HOLD THE * KEY WHILE THE TONE SOUNDS, DO NOT LET GO! The tone will change to an intermittent tone, then it will stop. Release the * key. CONGRATULATIONS!!! YOU ARE NOW IN PROGRAMMING MODE! _ _ _ _ _ PRESS STOR 1 SIDH 1 PRESS STOR 2 LOCAL 1 PRESS STOR 3 MIN MARK XXXXXXXXXX PRESS STOR 4 MIN 10 PRESS STOR 5 STATION 0334 PRESS STOR 6 IPCH 07 PRESS STOR 7 ACCOLC 0 PRESS STOR 8 PS 10 PRESS STOR 9 GIM 1234 PRESS STOR 10 LOCK 1 PRESS STOR 11 CALL TIME 2 PRESS STOR 12 AUTO LOCK 1 PRESS STOR 13 CALL REST PRESS STOR TO REVIEW ENTRIES. WHEN AT MODE #1 PRESS SEND TO BURN NAM AND RETURN TO NORMAL OPERATION. IF PROGRAMMING WAS DONE INCORRECTLY A SHORT HIGH TONE WILL BE HEARD, YOU MUST THEN REPEAT DATA ENTRY. YOU MUST PRESS STOR AFTER EACH ENTRY FOR THE CHECKSUM FUNCTION TO BE FULFILLED. Programming Instructions for: GENERAL ELECTRIC CARFONE XR3000 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THE UNLOCK CODE IS PROGRAMMED IN STEP 2 OF THE PROGRAMMING MODE PWR up unit Press "CL" and hold within 10 seconds of pwr up Enter "923885" Serial # will display Press Send key to advance to first entry XXXXXXXXXX Press SEND MIN 123 Press SEND UNLOCK _ _ _ _ _ Press SEND SID 1 Press SEND LU 1 Press SEND MIN MARK 334 Press SEND IPCH 07 Press SEND ACCOLC 0 Press SEND PS 10 Press SEND GIM 0 Press SEND AUX 1 Press SEND HANDS PRESS SEND TO REVIEW ENTRIES. NOTE: AREA CODE (402) WILL DISPLAY FOR MIN THEN AUTO SWITCH TO REST OF NUMBER ON DISPLAY - BE PATIENT PRESS "E" KEY TO COMPLETE PROGRAMMING OF THE XR 3000 AT THIS TIME Programming Instructions for: GOLDSTAR SERIES 5000 MOBILE ACTION TO STORE DISPLAY PWR up Unit Press FCN 4 to see the selected NAM. Press * to advance. Select NAM1. Press FCN, 9, 9, * "Enter Code" will be displayed. Enter 1234567890 XXXXXXXXXX PRESS MEM Enter MIN _ _ _ _ _ PRESS MEM Enter System ID 0334 PRESS MEM Enter IPCH 07 (ACCOLC) PRESS MEM Enter OVLD Class 1234 PRESS MEM LOCK CODE 123456 PRESS MEM SECURITY CODE 1234 PRESS MEM ALARM DISARM CODE 0 PRESS MEM PREFFERED SYSTEM 0 PRESS MEM STATION CLASS MARK 1 PRESS MEM HANDS FREE MARK (ON) 1 PRESS MEM LOCAL USE MARK (ON) 1 PRESS MEM MIN MARK (ON) 0 PRESS MEM HORN ALERT (OFF) 0 PRESS MEM OPT. SPEAKER (OFF) TO SAVE TO NAM NOW PRESS MEM TO REVIEW ENTRIES USE THE VOLUME UP OR DOWN KEYS Programming Instructions for: MITSUBISHI 555,560,600 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - TO PROGRAM THIS FUNCTION YOU MUST BE OUT OF THE PROGRAMMING MODE ENTER FCN 6 AND THEN ENTER THE NEW 3 DIGIT UNLOCK CODE PRESS CLR. To program from keypad remove and discard Nam Pad PWR up unit Press and Hold STO key within 10 seconds of pwr up Enter "5474432" Release STO key XXXXXXXXXX Press SEND MIN 123 Press SEND SECURITY CODE _ _ _ _ _ Press SEND SID 1 Press SEND LU 1 Press SEND MIN MARK 334 Press SEND IPCH1 07 Press SEND ACCOLC1 0 Press SEND PS1 10 Press SEND GIM 1 Press SEND EE 1 Press SEND HANDS FREE 0 Press SEND ROAM INHIBIT 0 Press SEND A/B SELECT 00 Press SEND f3-f0 DUAL HEAD 00 Press SEND f7-f4 LD INH TO EXIT PROGRAMMING MODE PRESS "END" AT ANY TIME Installing the LOCK CODE To program the customer's lock code, the phone must be out ot the programming mode. To program, enter FCN, 6,3-digit security code, the a 3-digit lock code. Press CLR. Programming Instructions for: NEC M3700 SERIES MOBILE ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - UNLOCK CODES WILL BE CHANGED ONLY IN PROGRAMMING MODE FOLLOW THE INSTRUCTIONS THAT FOLLOW A NAM PROGRAMMER ADAPTOR (NECAM #41-2012) IS REQUIRED PWR UP TO ENTER TEST MODE: RCL, #,0,1. WILL CYCLE TO SHADED TO CLEAR MEMORY: RCL # 3 9 select nam RCL # 7 6 0 # nam 1 RCL # 7 6 1 # nam 2 TO ENTER PROGRAMMING MODE: RCL #71 XXX XXX XXXX PRESS # Telephone No. (MIN) 1234 PRESS # Lock Code _ _ _ _ _ PRESS # Home Area (SYS I.D.) 10 PRESS # G-NO (Group I.D.) 0334 PRESS # First Paging Channel 0 for wireline PRESS # System Select 07 PRESS # ACCOLC 1 PRESS # ACCESS 1 PRESS # Local Use To exit PROGRAMMING MODE PRESS CLR and hold TEST MODE will show to exit TEST MODE RCL #02 IF MEM WAS CLEARED VIA RCL #39, PHONE WILL AUTOMATICALLY ENTER FULL-LOCK AFTER EXITING THE TEST MODE. TO UNLOCK PRESS FCN # 1234. Programming Instructions for: NOKIA LX-11 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - PRESS SEL,5 THEN ENTER 5 DIGIT SECURITY CODE PRESS SEL TO RECEIVE DISPLAY OF CURRENT UNLOCK CODE PRESS 5 NOW TO CLEAR ALL CALL TIMERS ENTER THE NEW UNLOCK CODE PRESS SEL TO ACCEPT PWR up unit Enter *3001#12345 Then - SEL 9 END IdEnt IF InFO should appear on display Pressing END will move you through the parameters Pressing SND will toggle between choices available _ _ _ _ _ Press END HO-Id (SID) 1 Press END ACCESS 1 Press END LOCL OPt XXXXXXXXXX Press END Phonxx 08 Press END St CLASS 334 Press END PAging Ch 07 Press END O-LOAd CLASS B Press END PrEF SyS 10 Press END grOUP Id 12345 Press END SECUrIty -------- (Can't be changed) Press END 1 dAtE 00/00/90 (INSTALLATION DATE) Press END 2 dAtE TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END" TO STORE LAST PARAMETER THEN POWER DOWN WHEN THE "END" KEY IS PRESSED FOLLOWING THE LAST PARAMETER, THE TEXT Prog donE WILL APPEAR ON DISPLAY Programming Instructions for: NOKIA M-10 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED BY THE SECURITY CODE PROGRAMMED AT THE TIME OF PROGRAMMING PWR up unit Enter *17*3001*1234* HO-Id must appear on display Press SEL to view current value Display will be one step behind TO STORE instructions _ _ _ _ _ Press SEL ACCESS (SID) 1 Press SEL LOCAL 1 Press SEL PhonE n XXXXXXXXXX Press SEL CLASS 08 Press SEL PAGE ch 334 Press SEL O-LOAd 07 Press SEL GrouP 10 Press SEL SEC 1234 Press SEL AUTO EXIT PROGRAM MODE TO EXIT PROGRAMMING MODE AT ANY TIME PRESS "END" WHEN THE SEL KEY IS PRESSED FOLLOWING THE LAST PARAMETER VALUE, THE PHONE WILL AUTOMATICALLY EXIT THE NAM PROGRAMMING MODE AND RETURN TO NORMAL OPERATION Programming Instructions for: NOVATEL 8305 TRANSPORTABLE CA08 SOFTWARE VERSION USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - IF EQUIPMENT IS PROVIDED WITH A MENU KEY THEN ENTER THE MENU PORTION OF THE PHONE AND DISPLAY AND IF NECESSARY REPROGRAM THE UNLOCK CODE FROM THERE. IF PHONE DOES NOT HAVE A MENU KEY THEN THERE CAN BE NO PROGRAMMING OF THE UNLOCK CODE... THE SECURITY CODE WILL BE ALL THAT IS PROVIDED Lock Phone by pressing FCN 1 Enter Programming Mode by pressing #259 Screen will display the software revision number Press Volume Up Screen will display Phone's E.S.N. Press Volume Up Screen will display INIT REP USE SND Press SEND to erase any numbers stored in the phones memory Press Volume Up _ _ _ _ _ Send Vol. Up SIDH system I.D. XXX XXX XXXX Send Vol. Up MIN mobile I.D. Must be changed when done Send Vol. Up LOCK CODE 1 programming - BY CUSTOMER Must be changed when done Send Vol. Up LOCK CODE 2 programming - BY CUSTOMER SET Vol. Up Option EX extnd adrss 334 press send to change Vol. Up IPCH initial pge 07 Send Vol. Up ACCOLC overload 10 Send Vol. Up GIM group i.d. 333 Vol. Up IDCCA initl a 334 Vol. Up IDCCB initl b 1 Vol. Up REG TBL SIZE Volume up through the four invalid System I.D. addresses SET Vol. Up OPTION LU local use B press send to change Vol. Up OPTION PS (prefered sys) CLR Vol. Up OPTION IRI rm inhbt CLR Vol. Up OPTION SSD SET Vol. Up OPTION QRC qck rcall SET Vol. Up OPTION QST qck store SET Vol. Up OPTION WUT wake tone SET Vol. Up OPTION EE use dtmf SET Vol. Up OPTION FD use dtmf SET Vol. Up OPTION MFD ext dtmf SET Vol. Up OPTION 32D dgt dial CLR Vol. Up OPTION MLH timer CLR Vol. Up OPTION LHM timer CLR Vol. Up OPTION CRU timer dsp CLR Vol. Up OPTION NLM timer SET for on CLR for off Vol. Up OPTION HA hrn alert CLR Vol. Up OPTION ONL diagnostc END to exit or VOLUME UP to review entries. Programming Instructions for: OKI CDL400 ACTION TO STORE DISPLAY To Enter Programming mode: Press IN SEQUENCE: END RCL FUNC CLR SND Screen shows Entr id Enter 08693427 XXX XXX XXXX PRESS # PRESS * PHon _ _ _ _ _ PRESS # PRESS * S id no 0334 PRESS # PRESS * iPCH 07 PRESS # PRESS * ACC oLC 123 PRESS # PRESS * LoC Cod 10 PRESS # PRESS * G id 0000 PRESS # PRESS * Stn CLS 0111 PRESS # PRESS * HORN ALERT, HANDS FREE, LOCAL USE, MIN. MARK. PRESS END AT THIS TIME TO EXIT PROGRAMMING MODE. __________________________________________________________________________ TO REPROGRAM TELEPHON NUMBER AND SYSTEM I.D. # - PRESS IN SEQUENCE THE FOLLOWING KEYSTROKES: FUNC 90 * 123 (SECURITY CODE) PHon WILL DISPLAY ENTER NEW PHONE NUMBER XXX XXX XXXX PRESS # PRESS * PHon _ _ _ _ _ PRESS # PRESS * S id no PRESS END AT THIS TIME TO EXIT PROGRAMMING MODE. ___________________________________________________________________________ To Re-Initialize Nam Memory for Handset Programmable Models - Func 99* Enter Last 8 digits of S.N. Press * Programming Instructions for: PANASONIC EB362 Charged Battery and Nam Adaptor(Grey Cord w/25pin Connector)are needed. ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE *0000# to enter program mode *1 Press SND 50 Press SND NAM 1 MODE _ _ _ _ _ Press STO 01 SIDH XXXXXXXXXX Press STO 02 OWNDL 1 2 3 Press STO 03 LOCK 0 0 0 0 0 0 0 0 0 0 0 0 (12) Press STO 04 SPDL 00 Press STO 05 SCM 334 Press STO 06 IPCH 07 Press STO 07 ACCOLC 10 Press STO 08 GIM 1 1 0 1 1 1 0 0 Press STO 09 FEATURE A 0 0 0 0 0 1 0 0 Press STO 10 FEATURE B 1 0 0 0 0 0 1 1 Press STO 11 FEATURE C 00 Press STO 12 DLMT STO ** Turn power off Programming Instructions for: PANASONIC EB-500 OR TP-500 ACTION TO STORE DISPLAY USED EQUIPMENT: TO DISPLAY CURRENT UNLOCK CODE - THIS FUNCTION IS PROVIDED FOR IN THE PROGRAMMING SEQUENCE Attach Nam Programmer Cable (Our Stock # 823) Pwr up unit Enter *0000# 0 *1 SND You are now in the NAM 1 Program mode. _ _ _ _ _ Press STO 01 S.I.D. XXXXXXXXXX Press STO 02 OWN # 0 Press STO 03 O for W/L system 334 Press STO 04 IPCH 07 Press STO 05 ACCOLC 10 Press STO 06 GIM 00 Press STO 07 Digit Dial Limit 08 Press STO 08 SCM (3watt i.d.) 911 Press STO 09 Rcl 00 1234 Press STO 10 Security Code 11000000 Press STO 11 FUNCTION BYTE 1 00010010 Press STO 12 FUNCTION BYTE 2 10010111 Press STO 13 FUNCTION BYTE 3 TO BURN NAM AT THIS TIME Press STO ** NAM is burned Turn off unit Detach programming cable Programming Instructions for: RADIO SHACK 17-1002 TRANSPORTABLE THIS UNIT REQUIRES A SERVICE HANDSET TO BE PROGRAMMED!!! A Mobira Service Handset (Modified) may be used. It is made from an ME53 or ME57 handset by opening and adding a jumper to the left of the one factory installed just below the white 24 pin connector joining the top and bottom PCB's. Also, pins 1 and 14 of the handset connector must be jumpered at the radio end. To disassemble the handset, carefully pry off the plastic earpad retaining housing to expose on hexdrive screw. Two other screws are under the rubber plugs at either side of the microphone. The handset then splits apart. This is a ticklish job and isn't recommended except in an extreme case and not with the customer's handset. The modification does not affect normal operation of the handset. It is not known if a Radio Shack handset will work the same. After the Service Handset has been applied - To enter LOCAL MODE (which takes the phone off the air and allows service commands to be obeyed) press 01#. The display should clear and noise is heard from the earpiece. To enter the NAM programming mode, enter 48#. The display shows 48 briefly and clears. ACTION TO STORE DISPLAY 0 _ _ _ _ _ PRESS * (5 Digit SID) 1 1 PRESS * 2 1 PRESS * 3 XXXXXXXXXX PRESS * 4 10 PRESS * 5 334 PRESS * 6 07 PRESS * 7 0 PRESS * 8 10 PRESS * 9 12345 PRESS * Press * to exit NAM Programming Mode and return to Local Mode. To enter the NAM reading Mode, press 49#. The display will show 49 Programming Instructions for: RADIO SHACK 17-1003 TRANSPORTABLE *17*1003* To enter program mode. If screen does not clear, enter 1234* Screen Programming Instructions for: UNIDEN CP- 900 THRU 5000 SERIES MOBILES AND TRANSPORTABLES THIS UNIT REQUIRES A PROGRAMMING HANDSET (MODEL CP-210 DIAGNOSTIC) Make sure the unit is properly connected to a 13.8 volt supply (cig lighter) and power on after utility handset is attached. Upon connecting utility handset to phone, the display will show 1 on the upper line and OP in the middle. You are now in the TEST MODE! Press SELECT, 2, SEND Top will show 2 0 and Current S.I.D. You are now in the PROGRAM MODE ACTION TO STORE DISPLAY 0 _ _ _ _ _ PRESS STORE SID 1 1 PRESS STORE LOCAL USE 2 1 PRESS STORE ACCES METH (MIN MARK) 3 XXXXXXXXXX PRESS STORE MIN 4 0334 PRESS STORE INITIAL PAGING CH 5 07 PRESS STORE ACCESS OVERLOAD 6 0 PRESS STORE PREF SYS (O-B,1-A) 7 10 PRESS STORE GROUP I.D. MARK 8 1234 PRESS STORE LOCK CODE (SEE re:) 9 1 PRESS STORE DTMF DURATION A 0 PRESS STORE AUTO SHUT-OFF Enter the data for the selected item. If an error is made during data entry the CLR key can be used to erase single keys. PRESS SEND to burn NAM. Phone will display PASS. If FAIL is displayed you must repeat programming sequence. To read the NAM (review) press SELECT 3 SEND. Enter RCL then the number of the item that you wish to view. Press the CLR key to exit and return to test mode. TO VIEW THE SERIAL NUMBER OF THE UNIT BEING PROGRAMMED - Press SELECT 4 SEND while in the Test Mode to display the phone's serial number in decimal form. The manufacturer ID (172) will be displayed on the top line while the remainder of the serial number will appear on the bottom line Press the CLR key to return to the Test Mode display. ------------------------------------------------------------------------------- DEFINITIONS: XXX - Area Code or Prefix XXXXXXX - Prefix & Suffix XXXXXXXXXX - Area Code, Prefix, & Suffix _ _ _ _ _ - Digits (One Line Per Digit [Sample To Left Is 5 Digits]) MIN* (Mobile Identification Number): 10 digit directory telephone number. UNLOCK (Lock Code): 3 digit code to unlock radio (WARNING - The radio cannot be unlocked if this code is forgotten). NOTE: You can read this code by using the programming procedure. SID* (Home System Identification): 5 digit number for assigned cellular system. LU* (Local Use): 0 or 1. 1=local control option and responds to local control messages. MIN MARK* 0 or 1. 1=home station sends extended address information upon origination and page response. IPCH* (Initial Paging Channel in Home): 3 digit number to identify the channel number of the first paging channel when station is home. ACCOLC* (Access Overload Class): 2 digit number to identify which overload class field controls the access attempts. PS* (Perferred System): 0 or 1. 1=Preferred system is System A 0=Preferred system is System B GIM* (Group Identification Mark): 2 digit number which indicates how many bits of SID, starting with the most significant, comprise the GIM. AUX 0 or 1. 1=Auxiliary signal is enabled for horn relay. External adapter must be used for this feature. HANDS 0 or 1. 1=Handsfree feature is enabled. External adapter must be used for this feature. ALT LOCK (Alternate Lock Code): 3 digit lock code to be used with the partial lock feature. This feature is active only with the GE CF-2000 and CF-2500 Carfone models. This entry is ignored for GE CF-1000 Carfone models. *These values are Cellular System dependent. Entering an incorrect value will deny service on the system. * * * * * * * * * * * * * * * W A R N I N G * * * * * * * * * * * * * * * * * * When a cellular phone transmits, it sends its Electronic Identification Number and its assigned telephone number back to the cellular phone companys computer. This leaves an electronic trail. If the phone is registered to you and you change the phone number you run a risk of being tracked by the Electronic Identification Number. If the phone is not registered to you, you can be tracked by the numbers you call frequently. It wouldn't be very smart to phone home to see how the little woman is doing or check to see if the latest software came on UPS. And remember, when you use a cellular phone it goes out over the airways. This means anyone with the know-how can listen to you. All some people need is a juicy bit of information and a phone number and you leave yourself open to all kinds of scams, blackmail, and legal problems. * * * M O R E * N O T E S * * * Most cellular companys do not turn off the numbers that are not in use. Better yet I do not know of a company that tracks numbers that are not assigned. They seem to keep the low numbers filled in. When someone turns in a phone they reassign that number instead of a new number. If you put a number in your phone, use a high number. Chances are it is not assigned to anyone. The calls you make on a unassigned number usually will go unnoticed. Better yet monitor the number you wish to use with a scanner for a period of time to check for activity. Happy foning.....